T1 - A histological and clinical comparison of new and conventional integrated backscatter intravascular ultrasound (IB-IVUS)
AU - Ohota, Masaya
AU - Kawasaki, Masanori
AU - Ismail, Tevfik F.
AU - Hattori, Kousuke
AU - Serruys, Patrick W.
AU - Ozaki, Yukio
PY - 2012
Y1 - 2012
N2 - Background: While the utilization of integrated backscatter intravascular ultrasound (IB-IVUS) for the quantitative in vivo assessment of coronary plaque continues to grow, the validity of IB-IVUS images obtained from newly developed and conventional systems remains uncertain. Methods and Results: To assess the accuracy and reliability of a newly developed IB-IVUS system (VISIWAVE) as compared to the conventional system (Clearview), we compared quantitative IB-IVUS plaque characteristics in the 2 systems using 125 post-mortem specimens from 26 coronary arteries in 11 cadavers, as well as using 200 clinical plaques in 32 patients undergoing coronary intervention. The overall agreement between the histological and IB-IVUS diagnoses using VISIWAVE (Cohen's κ=0.82, 95%CI: 0.73-0.90) was similar to that using Clearview (Cohen's κ=0.80, 95%CI: 0.71-0.89). The 2 systems also demonstrated comparably high sensitivity and specificity. In the direct comparison, the overall agreement between IB-IVUS diagnoses using VISIWAVE and Clearview was also excellent (Cohen's κ=0.87, 95%CI: 0.78-0.95). In the clinical comparison, measured plaque dimensions were similar (VISIWAVE: 8.27±3.46 mm 2 vs. Clearview; 8.31±3.46 mm 2, P=0.44) and there was strong concordance between both greyscale and IB-IVUS parameters. Conclusions: There was close agreement of analyzed results in both systems when compared with the gold standard of histology. Both systems are able to reliably and accurately characterize coronary plaque and thereby make a valuable contribution to our understanding of atherosclerosis.
AB - Background: While the utilization of integrated backscatter intravascular ultrasound (IB-IVUS) for the quantitative in vivo assessment of coronary plaque continues to grow, the validity of IB-IVUS images obtained from newly developed and conventional systems remains uncertain. Methods and Results: To assess the accuracy and reliability of a newly developed IB-IVUS system (VISIWAVE) as compared to the conventional system (Clearview), we compared quantitative IB-IVUS plaque characteristics in the 2 systems using 125 post-mortem specimens from 26 coronary arteries in 11 cadavers, as well as using 200 clinical plaques in 32 patients undergoing coronary intervention. The overall agreement between the histological and IB-IVUS diagnoses using VISIWAVE (Cohen's κ=0.82, 95%CI: 0.73-0.90) was similar to that using Clearview (Cohen's κ=0.80, 95%CI: 0.71-0.89). The 2 systems also demonstrated comparably high sensitivity and specificity. In the direct comparison, the overall agreement between IB-IVUS diagnoses using VISIWAVE and Clearview was also excellent (Cohen's κ=0.87, 95%CI: 0.78-0.95). In the clinical comparison, measured plaque dimensions were similar (VISIWAVE: 8.27±3.46 mm 2 vs. Clearview; 8.31±3.46 mm 2, P=0.44) and there was strong concordance between both greyscale and IB-IVUS parameters. Conclusions: There was close agreement of analyzed results in both systems when compared with the gold standard of histology. Both systems are able to reliably and accurately characterize coronary plaque and thereby make a valuable contribution to our understanding of atherosclerosis.
UR - http://www.scopus.com/inward/record.url?scp=84863198042&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=84863198042&partnerID=8YFLogxK
U2 - 10.1253/circj.CJ-11-1157
DO - 10.1253/circj.CJ-11-1157
M3 - Article
C2 - 22510819
AN - SCOPUS:84863198042
SN - 1346-9843
VL - 76
SP - 1678
EP - 1686
JO - Circulation Journal
JF - Circulation Journal
IS - 7
ER -