Abstract

Gait reconstruction systems for paraplegics have been attempted to improve their activities of daily lives. The stride control based on the user's intension is important to coordinate the voluntary movements of the user and the assisted movements of paralyzed legs. Assuming that the intended stride is equal to the distance of the preceding an arm movement, we developed a human interface estimating the distance of the arm movement using an accelerometer. The locomotor device is controlled so that the stride length is equal to the arm movement distance. In the current work, we examine a human interface and a control system of a locomotor device. A hand distance is estimated through polynomial fitting of the arm acceleration based on the criterion of smoothness. Here, we report two experimental results; (1) evaluation of the estimation accuracy, (2) validation of the control system of the locomotor device. Comparing the estimation accuracy of polynomial fitting with that of a twice integral method, the estimation of the polynomial fitting method shows good consistency with the measured distance. In addition, we confirmed that the stirde length can be controlled through the voluntary arm acceleration. These results suggest that the proposed human interface is effective for a paraplegic locomotor device.

Original languageEnglish
Title of host publication3rd International Symposium on Measurement, Analysis, and Modeling of Human Functions 2007, ISHF 2007
Pages154-159
Number of pages6
Publication statusPublished - 01-12-2007
Event3rd International Symposium on Measurement, Analysis, and Modeling of Human Functions 2007, ISHF 2007 - Lisbon, Portugal
Duration: 14-06-200716-06-2007

Other

Other3rd International Symposium on Measurement, Analysis, and Modeling of Human Functions 2007, ISHF 2007
CountryPortugal
CityLisbon
Period14-06-0716-06-07

Fingerprint

Human Interface
Polynomials
Control systems
Polynomial
Accelerometers
Control System
Integral Method
Accelerometer
Gait
Smoothness
Movement
Evaluation
Experimental Results

All Science Journal Classification (ASJC) codes

  • Modelling and Simulation

Cite this

Kagawa, T., Uno, Y., Muraoka, Y., & Saitoh, E. (2007). A human interface predicting intended strides for a paraplegic locomotor device. In 3rd International Symposium on Measurement, Analysis, and Modeling of Human Functions 2007, ISHF 2007 (pp. 154-159)
Kagawa, Takahiro ; Uno, Yoji ; Muraoka, Yoshihiro ; Saitoh, Eiichi. / A human interface predicting intended strides for a paraplegic locomotor device. 3rd International Symposium on Measurement, Analysis, and Modeling of Human Functions 2007, ISHF 2007. 2007. pp. 154-159
@inproceedings{6512527408b74b41b013cc53492ab060,
title = "A human interface predicting intended strides for a paraplegic locomotor device",
abstract = "Gait reconstruction systems for paraplegics have been attempted to improve their activities of daily lives. The stride control based on the user's intension is important to coordinate the voluntary movements of the user and the assisted movements of paralyzed legs. Assuming that the intended stride is equal to the distance of the preceding an arm movement, we developed a human interface estimating the distance of the arm movement using an accelerometer. The locomotor device is controlled so that the stride length is equal to the arm movement distance. In the current work, we examine a human interface and a control system of a locomotor device. A hand distance is estimated through polynomial fitting of the arm acceleration based on the criterion of smoothness. Here, we report two experimental results; (1) evaluation of the estimation accuracy, (2) validation of the control system of the locomotor device. Comparing the estimation accuracy of polynomial fitting with that of a twice integral method, the estimation of the polynomial fitting method shows good consistency with the measured distance. In addition, we confirmed that the stirde length can be controlled through the voluntary arm acceleration. These results suggest that the proposed human interface is effective for a paraplegic locomotor device.",
author = "Takahiro Kagawa and Yoji Uno and Yoshihiro Muraoka and Eiichi Saitoh",
year = "2007",
month = "12",
day = "1",
language = "English",
isbn = "9781615676767",
pages = "154--159",
booktitle = "3rd International Symposium on Measurement, Analysis, and Modeling of Human Functions 2007, ISHF 2007",

}

Kagawa, T, Uno, Y, Muraoka, Y & Saitoh, E 2007, A human interface predicting intended strides for a paraplegic locomotor device. in 3rd International Symposium on Measurement, Analysis, and Modeling of Human Functions 2007, ISHF 2007. pp. 154-159, 3rd International Symposium on Measurement, Analysis, and Modeling of Human Functions 2007, ISHF 2007, Lisbon, Portugal, 14-06-07.

A human interface predicting intended strides for a paraplegic locomotor device. / Kagawa, Takahiro; Uno, Yoji; Muraoka, Yoshihiro; Saitoh, Eiichi.

3rd International Symposium on Measurement, Analysis, and Modeling of Human Functions 2007, ISHF 2007. 2007. p. 154-159.

Research output: Chapter in Book/Report/Conference proceedingConference contribution

TY - GEN

T1 - A human interface predicting intended strides for a paraplegic locomotor device

AU - Kagawa, Takahiro

AU - Uno, Yoji

AU - Muraoka, Yoshihiro

AU - Saitoh, Eiichi

PY - 2007/12/1

Y1 - 2007/12/1

N2 - Gait reconstruction systems for paraplegics have been attempted to improve their activities of daily lives. The stride control based on the user's intension is important to coordinate the voluntary movements of the user and the assisted movements of paralyzed legs. Assuming that the intended stride is equal to the distance of the preceding an arm movement, we developed a human interface estimating the distance of the arm movement using an accelerometer. The locomotor device is controlled so that the stride length is equal to the arm movement distance. In the current work, we examine a human interface and a control system of a locomotor device. A hand distance is estimated through polynomial fitting of the arm acceleration based on the criterion of smoothness. Here, we report two experimental results; (1) evaluation of the estimation accuracy, (2) validation of the control system of the locomotor device. Comparing the estimation accuracy of polynomial fitting with that of a twice integral method, the estimation of the polynomial fitting method shows good consistency with the measured distance. In addition, we confirmed that the stirde length can be controlled through the voluntary arm acceleration. These results suggest that the proposed human interface is effective for a paraplegic locomotor device.

AB - Gait reconstruction systems for paraplegics have been attempted to improve their activities of daily lives. The stride control based on the user's intension is important to coordinate the voluntary movements of the user and the assisted movements of paralyzed legs. Assuming that the intended stride is equal to the distance of the preceding an arm movement, we developed a human interface estimating the distance of the arm movement using an accelerometer. The locomotor device is controlled so that the stride length is equal to the arm movement distance. In the current work, we examine a human interface and a control system of a locomotor device. A hand distance is estimated through polynomial fitting of the arm acceleration based on the criterion of smoothness. Here, we report two experimental results; (1) evaluation of the estimation accuracy, (2) validation of the control system of the locomotor device. Comparing the estimation accuracy of polynomial fitting with that of a twice integral method, the estimation of the polynomial fitting method shows good consistency with the measured distance. In addition, we confirmed that the stirde length can be controlled through the voluntary arm acceleration. These results suggest that the proposed human interface is effective for a paraplegic locomotor device.

UR - http://www.scopus.com/inward/record.url?scp=84871347985&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=84871347985&partnerID=8YFLogxK