T1 - A pivot bearing-supported centrifugal pump for a long-term assist heart
AU - Nakazawa, T.
AU - Ohara, Y.
AU - Benkowski, R.
AU - Makinouchi, K.
AU - Takami, Y.
AU - Ohtsubo, S.
AU - Kawahito, K.
AU - Tasai, K.
AU - Glueck, J.
AU - Noon, G. P.
AU - Sueoka, A.
AU - Schmallegger, H.
AU - Schima, H.
AU - Wolner, E.
AU - Nosé, Y.
PY - 1997/4
Y1 - 1997/4
N2 - A pivot bearing-supported centrifugal blood pump has been developed. It is a compact, cost effective, and anti-thrombogenic pump with anatomical compatibility A preliminary evaluation of five paracorporeal left ventricular assist studies were performed on pre-conditioned bovine (70-100 kg), without cardiopulmonary bypass and aortic cross-clamping. The inflow cannula was inserted into the left ventricle (LV) through the apex and the outflow cannula affixed with a Dacron vascular graft was anastomosed to the descending aorta. All pumps demonstrated trouble free performance over a two week screening period. Among these five studies, three implantations were subjected for one month system validation studies. All the devices were trouble free for longer than 1 month (35, 34 and 31 days). After achieving one month studies, all experiments were terminated. There was no evidence of device induced thrombus formation inside the pump. The plasma free hemoglobin levels were within normal ranges throughout all experiments. As a consequence of these studies, a mass production model C1E3 of this pump was fabricated as a short-term assist pump. This pump has a Normalized Index of Hemolysis of 0.0007 mg/100L and the estimated wear life of the impeller bearings is longer than 8 years. The C1E3 will meet the clinical requirements as a cardiopulmonary bypass pump. For the next step a miniaturized pivot bearing centrifugal blood pump PI-601 has been developed for use as a permanently implantable device after design optimization. The evolution from C1E3 to the PI-601 converts this pivot bearing centrifugal pump as a totally implantable centrifugal pump A pivot bearing centrifugal pump will become an ideal assist pump for the patients with failing heart.
AB - A pivot bearing-supported centrifugal blood pump has been developed. It is a compact, cost effective, and anti-thrombogenic pump with anatomical compatibility A preliminary evaluation of five paracorporeal left ventricular assist studies were performed on pre-conditioned bovine (70-100 kg), without cardiopulmonary bypass and aortic cross-clamping. The inflow cannula was inserted into the left ventricle (LV) through the apex and the outflow cannula affixed with a Dacron vascular graft was anastomosed to the descending aorta. All pumps demonstrated trouble free performance over a two week screening period. Among these five studies, three implantations were subjected for one month system validation studies. All the devices were trouble free for longer than 1 month (35, 34 and 31 days). After achieving one month studies, all experiments were terminated. There was no evidence of device induced thrombus formation inside the pump. The plasma free hemoglobin levels were within normal ranges throughout all experiments. As a consequence of these studies, a mass production model C1E3 of this pump was fabricated as a short-term assist pump. This pump has a Normalized Index of Hemolysis of 0.0007 mg/100L and the estimated wear life of the impeller bearings is longer than 8 years. The C1E3 will meet the clinical requirements as a cardiopulmonary bypass pump. For the next step a miniaturized pivot bearing centrifugal blood pump PI-601 has been developed for use as a permanently implantable device after design optimization. The evolution from C1E3 to the PI-601 converts this pivot bearing centrifugal pump as a totally implantable centrifugal pump A pivot bearing centrifugal pump will become an ideal assist pump for the patients with failing heart.
UR - http://www.scopus.com/inward/record.url?scp=8244224537&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=8244224537&partnerID=8YFLogxK
U2 - 10.1177/039139889702000407
DO - 10.1177/039139889702000407
M3 - Article
C2 - 9195240
AN - SCOPUS:8244224537
SN - 0391-3988
VL - 20
SP - 222
EP - 228
JO - International Journal of Artificial Organs
JF - International Journal of Artificial Organs
IS - 4
ER -