A trial of89Sr bremsstrahlung SPECT

Seiichiro Ota, Hiroshi Toyama, Masaki Uno, Masaki Kato, Masanobu Ishiguro, Takahiro Natsume, Fumitaka Ito, Kaoru Kikukawa, Masanori Tadokoro, Takashi Ichihara, Kazuhiro Katada

Research output: Contribution to journalArticle

3 Citations (Scopus)

Abstract

Objective: 89Sr bremsstrahlung SPECT imaging has been evaluated for detecting the more detailed whole body 89Sr distribution. Methods: 89Sr bremsstrahlung whole body planar and merged SPECT images were acquired by using two detectors type SPECT system. Energy window A (100 keV ±50%) for planar imaging, and energy window A plus adjacent energy window B (300 keV±50%) for SPECT imaging were set on the continuous spectrum. Those images were compared with 99mTc-H-MDP whole body planar and merged SPECT images. To verify the accumulation obtained by bremsstrahlung whole body planar and merged SPECT image, we made original phantom based on the counts of clinical study imaging. Results: On 89Sr bremsstrahlung merged SPECT image, focal accumulations were recognized in the parts of 99mTc-H-MDP merged SPECT accumulation. Focal accumulations were much clearer on 89Sr bremsstrahlung merged SPECT imaging than those of whole body planar image Of 89Sr bremsstrahlung. In phantom study, counts of each concentration linearly increase as acquisition time and number of rotation increase on planar and SPECT images. Conclusions: 89Sr bremsstrahlung merged SPECT imaging would be useful for detecting the more detailed whole body 89Sr distribution.

Original languageEnglish
Pages (from-to)101-107
Number of pages7
JournalKakuigaku
Volume48
Issue number2
Publication statusPublished - 01-05-2011

Fingerprint

Single-Photon Emission-Computed Tomography
Technetium Tc 99m Medronate
Body Image

All Science Journal Classification (ASJC) codes

  • Medicine(all)

Cite this

Ota, S., Toyama, H., Uno, M., Kato, M., Ishiguro, M., Natsume, T., ... Katada, K. (2011). A trial of89Sr bremsstrahlung SPECT. Kakuigaku, 48(2), 101-107.
Ota, Seiichiro ; Toyama, Hiroshi ; Uno, Masaki ; Kato, Masaki ; Ishiguro, Masanobu ; Natsume, Takahiro ; Ito, Fumitaka ; Kikukawa, Kaoru ; Tadokoro, Masanori ; Ichihara, Takashi ; Katada, Kazuhiro. / A trial of89Sr bremsstrahlung SPECT. In: Kakuigaku. 2011 ; Vol. 48, No. 2. pp. 101-107.
@article{900bf0da32bb468696a2faeec9395c8a,
title = "A trial of89Sr bremsstrahlung SPECT",
abstract = "Objective: 89Sr bremsstrahlung SPECT imaging has been evaluated for detecting the more detailed whole body 89Sr distribution. Methods: 89Sr bremsstrahlung whole body planar and merged SPECT images were acquired by using two detectors type SPECT system. Energy window A (100 keV ±50{\%}) for planar imaging, and energy window A plus adjacent energy window B (300 keV±50{\%}) for SPECT imaging were set on the continuous spectrum. Those images were compared with 99mTc-H-MDP whole body planar and merged SPECT images. To verify the accumulation obtained by bremsstrahlung whole body planar and merged SPECT image, we made original phantom based on the counts of clinical study imaging. Results: On 89Sr bremsstrahlung merged SPECT image, focal accumulations were recognized in the parts of 99mTc-H-MDP merged SPECT accumulation. Focal accumulations were much clearer on 89Sr bremsstrahlung merged SPECT imaging than those of whole body planar image Of 89Sr bremsstrahlung. In phantom study, counts of each concentration linearly increase as acquisition time and number of rotation increase on planar and SPECT images. Conclusions: 89Sr bremsstrahlung merged SPECT imaging would be useful for detecting the more detailed whole body 89Sr distribution.",
author = "Seiichiro Ota and Hiroshi Toyama and Masaki Uno and Masaki Kato and Masanobu Ishiguro and Takahiro Natsume and Fumitaka Ito and Kaoru Kikukawa and Masanori Tadokoro and Takashi Ichihara and Kazuhiro Katada",
year = "2011",
month = "5",
day = "1",
language = "English",
volume = "48",
pages = "101--107",
journal = "Kaku igaku. The Japanese journal of nuclear medicine",
issn = "0022-7854",
publisher = "Japanese Society of Nuclear Medicine",
number = "2",

}

Ota, S, Toyama, H, Uno, M, Kato, M, Ishiguro, M, Natsume, T, Ito, F, Kikukawa, K, Tadokoro, M, Ichihara, T & Katada, K 2011, 'A trial of89Sr bremsstrahlung SPECT', Kakuigaku, vol. 48, no. 2, pp. 101-107.

A trial of89Sr bremsstrahlung SPECT. / Ota, Seiichiro; Toyama, Hiroshi; Uno, Masaki; Kato, Masaki; Ishiguro, Masanobu; Natsume, Takahiro; Ito, Fumitaka; Kikukawa, Kaoru; Tadokoro, Masanori; Ichihara, Takashi; Katada, Kazuhiro.

In: Kakuigaku, Vol. 48, No. 2, 01.05.2011, p. 101-107.

Research output: Contribution to journalArticle

TY - JOUR

T1 - A trial of89Sr bremsstrahlung SPECT

AU - Ota, Seiichiro

AU - Toyama, Hiroshi

AU - Uno, Masaki

AU - Kato, Masaki

AU - Ishiguro, Masanobu

AU - Natsume, Takahiro

AU - Ito, Fumitaka

AU - Kikukawa, Kaoru

AU - Tadokoro, Masanori

AU - Ichihara, Takashi

AU - Katada, Kazuhiro

PY - 2011/5/1

Y1 - 2011/5/1

N2 - Objective: 89Sr bremsstrahlung SPECT imaging has been evaluated for detecting the more detailed whole body 89Sr distribution. Methods: 89Sr bremsstrahlung whole body planar and merged SPECT images were acquired by using two detectors type SPECT system. Energy window A (100 keV ±50%) for planar imaging, and energy window A plus adjacent energy window B (300 keV±50%) for SPECT imaging were set on the continuous spectrum. Those images were compared with 99mTc-H-MDP whole body planar and merged SPECT images. To verify the accumulation obtained by bremsstrahlung whole body planar and merged SPECT image, we made original phantom based on the counts of clinical study imaging. Results: On 89Sr bremsstrahlung merged SPECT image, focal accumulations were recognized in the parts of 99mTc-H-MDP merged SPECT accumulation. Focal accumulations were much clearer on 89Sr bremsstrahlung merged SPECT imaging than those of whole body planar image Of 89Sr bremsstrahlung. In phantom study, counts of each concentration linearly increase as acquisition time and number of rotation increase on planar and SPECT images. Conclusions: 89Sr bremsstrahlung merged SPECT imaging would be useful for detecting the more detailed whole body 89Sr distribution.

AB - Objective: 89Sr bremsstrahlung SPECT imaging has been evaluated for detecting the more detailed whole body 89Sr distribution. Methods: 89Sr bremsstrahlung whole body planar and merged SPECT images were acquired by using two detectors type SPECT system. Energy window A (100 keV ±50%) for planar imaging, and energy window A plus adjacent energy window B (300 keV±50%) for SPECT imaging were set on the continuous spectrum. Those images were compared with 99mTc-H-MDP whole body planar and merged SPECT images. To verify the accumulation obtained by bremsstrahlung whole body planar and merged SPECT image, we made original phantom based on the counts of clinical study imaging. Results: On 89Sr bremsstrahlung merged SPECT image, focal accumulations were recognized in the parts of 99mTc-H-MDP merged SPECT accumulation. Focal accumulations were much clearer on 89Sr bremsstrahlung merged SPECT imaging than those of whole body planar image Of 89Sr bremsstrahlung. In phantom study, counts of each concentration linearly increase as acquisition time and number of rotation increase on planar and SPECT images. Conclusions: 89Sr bremsstrahlung merged SPECT imaging would be useful for detecting the more detailed whole body 89Sr distribution.

UR - http://www.scopus.com/inward/record.url?scp=79960023565&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=79960023565&partnerID=8YFLogxK

M3 - Article

VL - 48

SP - 101

EP - 107

JO - Kaku igaku. The Japanese journal of nuclear medicine

JF - Kaku igaku. The Japanese journal of nuclear medicine

SN - 0022-7854

IS - 2

ER -