T1 - Accuracy and reliability of continuous blood glucose monitor in post-surgical patients
AU - Yamashita, K.
AU - Okabayashi, T.
AU - Yokoyama, T.
AU - Yatabe, T.
AU - Maeda, H.
AU - Manabe, M.
AU - Hanazaki, K.
PY - 2009/1
Y1 - 2009/1
N2 - Background: The STG-22™ is the only continuous blood glucose monitoring system currently available. The aim of this study is to determine the accuracy and reliability of the STG-22™ for continuously monitoring blood glucose level in post-surgical patients. Methods: Fifty patients scheduled for routine surgery were studied in surgical intensive care unit (ICU) of a university hospital. After admission to the ICU, the STG-22™ was connected to the patients. An attending physician obtained blood samples from a radial arterial catheter. Blood glucose level was measured using the ABL™800FLEX immediately after blood collection at 0, 4, 8, and 16 h post-admission to the ICU (total of 200 blood glucose values). Results: The correlation coefficient (R2) was 0.96. In the Clarke error grid, 100% of the paired measurements were in the clinically acceptable zone A and B. The Bland and Altman analysis showed that bias±limits of agreement (percent error) were 0.04(0.7)±0.35(6.3) mmol (mg/dl) (7%), -0.11(-2)±1.22(22) (15%) and -0.33(-6)±1.28(23) (10%) in hypoglycemia (<70(3.89) mmol (mg/dl), normoglycemia (3.89(70)-10(180) mmol (mg/dl), and hyperglycemia (>10(180) mmol (mg/dl), respectively. Conclusions: The STG-22™ can be used for measuring blood glucose level continuously and measurement results are consistent with intermittent measurement (percentage error within 15%). Therefore, the STG-22™ is a useful device for monitoring in blood glucose level in the ICU for 16 h.
AB - Background: The STG-22™ is the only continuous blood glucose monitoring system currently available. The aim of this study is to determine the accuracy and reliability of the STG-22™ for continuously monitoring blood glucose level in post-surgical patients. Methods: Fifty patients scheduled for routine surgery were studied in surgical intensive care unit (ICU) of a university hospital. After admission to the ICU, the STG-22™ was connected to the patients. An attending physician obtained blood samples from a radial arterial catheter. Blood glucose level was measured using the ABL™800FLEX immediately after blood collection at 0, 4, 8, and 16 h post-admission to the ICU (total of 200 blood glucose values). Results: The correlation coefficient (R2) was 0.96. In the Clarke error grid, 100% of the paired measurements were in the clinically acceptable zone A and B. The Bland and Altman analysis showed that bias±limits of agreement (percent error) were 0.04(0.7)±0.35(6.3) mmol (mg/dl) (7%), -0.11(-2)±1.22(22) (15%) and -0.33(-6)±1.28(23) (10%) in hypoglycemia (<70(3.89) mmol (mg/dl), normoglycemia (3.89(70)-10(180) mmol (mg/dl), and hyperglycemia (>10(180) mmol (mg/dl), respectively. Conclusions: The STG-22™ can be used for measuring blood glucose level continuously and measurement results are consistent with intermittent measurement (percentage error within 15%). Therefore, the STG-22™ is a useful device for monitoring in blood glucose level in the ICU for 16 h.
UR - http://www.scopus.com/inward/record.url?scp=57649217580&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=57649217580&partnerID=8YFLogxK
U2 - 10.1111/j.1399-6576.2008.01799.x
DO - 10.1111/j.1399-6576.2008.01799.x
M3 - Article
C2 - 19032568
AN - SCOPUS:57649217580
SN - 0001-5172
VL - 53
SP - 66
EP - 71
JO - Acta Anaesthesiologica Scandinavica
JF - Acta Anaesthesiologica Scandinavica
IS - 1
ER -