TY - JOUR
T1 - Accuracy of quantitative echocardiographic measures of right ventricular function as compared to cardiovascular magnetic resonance
AU - Hamilton-Craig, Christian R.
AU - Stedman, Kathy
AU - Maxwell, Ryan
AU - Anderson, Bonita
AU - Stanton, Tony
AU - Chan, Jonathan
AU - Yamada, Akira
AU - Scalia, Gregory M.
AU - Burstow, Darryl J.
N1 - Publisher Copyright:
© 2016 Published by Elsevier Ireland Ltd.
PY - 2016/9/1
Y1 - 2016/9/1
N2 - Background: Many echocardiographic parameters have been proposed to evaluate right ventricular (RV) systolic function. We comprehensively assessed a wide range of quantitative echocardiographic parameters in a single cohort compared with same-day cardiovascular magnetic resonance (CMR). Methods and results: 92 subjects were examined prospectively: Group 1 consisted of 46 healthy controls (21 males, 33.4 ± 11.4 years), Group 2 consisted of 46 patients (20 males, 38.5 ± 18.9 years) undergoing RV functional assessment by CMR (1.5 T). Echocardiography was performed on the same day as CMR; fractional area change (RVFAC), myocardial performance index via spectral Doppler (RVMPI), RVMPI via Doppler tissue imaging (RVMPI-DTI), peak systolic myocardial velocity by DTI (RVSm), tricuspid annular plane systolic excursion (TAPSE), speckle tracking strain, and three dimensional right ventricular ejection fraction (3DE-RV). Linear regression, Bland-Altman and receiver-operator-characteristic (ROC) analyses were performed. At ROC analysis, the most predictive echocardiographic methods were; RVFAC (AUC = 0.892), RVMPI (AUC 0.785), TAPSE (AUC 0.849) and 3DE-RV (AUC 0.909). 3DE-RV appeared the most accurate compared to CMR, although underestimated true RV volumes. Conclusion: As compared to CMR; 3DE-RV, RVFAC, TAPSE and RVMPI were the most reliable predictors of RV function. These parameters can be recommended for clinical use.
AB - Background: Many echocardiographic parameters have been proposed to evaluate right ventricular (RV) systolic function. We comprehensively assessed a wide range of quantitative echocardiographic parameters in a single cohort compared with same-day cardiovascular magnetic resonance (CMR). Methods and results: 92 subjects were examined prospectively: Group 1 consisted of 46 healthy controls (21 males, 33.4 ± 11.4 years), Group 2 consisted of 46 patients (20 males, 38.5 ± 18.9 years) undergoing RV functional assessment by CMR (1.5 T). Echocardiography was performed on the same day as CMR; fractional area change (RVFAC), myocardial performance index via spectral Doppler (RVMPI), RVMPI via Doppler tissue imaging (RVMPI-DTI), peak systolic myocardial velocity by DTI (RVSm), tricuspid annular plane systolic excursion (TAPSE), speckle tracking strain, and three dimensional right ventricular ejection fraction (3DE-RV). Linear regression, Bland-Altman and receiver-operator-characteristic (ROC) analyses were performed. At ROC analysis, the most predictive echocardiographic methods were; RVFAC (AUC = 0.892), RVMPI (AUC 0.785), TAPSE (AUC 0.849) and 3DE-RV (AUC 0.909). 3DE-RV appeared the most accurate compared to CMR, although underestimated true RV volumes. Conclusion: As compared to CMR; 3DE-RV, RVFAC, TAPSE and RVMPI were the most reliable predictors of RV function. These parameters can be recommended for clinical use.
UR - http://www.scopus.com/inward/record.url?scp=84975230080&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=84975230080&partnerID=8YFLogxK
U2 - 10.1016/j.ijcha.2016.05.007
DO - 10.1016/j.ijcha.2016.05.007
M3 - Article
AN - SCOPUS:84975230080
SN - 2352-9067
VL - 12
SP - 38
EP - 44
JO - IJC Heart and Vasculature
JF - IJC Heart and Vasculature
ER -