T1 - Analysis of the heart rate variability during cryoballoon ablation of atrial fibrillation
AU - Mori, Hitoshi
AU - Kato, Ritsushi
AU - Ikeda, Yoshifumi
AU - Goto, Koji
AU - Tanaka, Sayaka
AU - Asano, So
AU - Shiki, Yuichiro
AU - Nagase, Takahiko
AU - Iwanaga, Shiro
AU - Nishimura, Shigeyuki
AU - Muramatsu, Toshihiro
AU - Matsumoto, Kazuo
N1 - Publisher Copyright:
© 2017 The Author(s).
PY - 2018/8/1
Y1 - 2018/8/1
N2 - Aims: Vagal responses such as marked bradycardia or a rapid blood pressure decrease are often observed during pulmonary vein (PV) isolation of atrial fibrillation (AF) using a cryoballoon (CB). However, the relationship between the marked vagal response and change in the heart rate variability (HRV) as a marker of the autonomic tone is not well understood. Methods and results: Fifty-four paroxysmal AF patients underwent CB ablation. The CB ablation was started from the right sided PVs in 25 patients (R group) and left sided PVs in 29 (L group). The HRV and haemodynamic status during the procedure were analysed. A vagal response was observed in 16 L group patients (61.5%) during the ablation of the different PVs (RSPV:1, RIPV:5, LSPV:15, LIPV:5), while it was observed in only 2 R group patients (9.5%) (RSPV:0, RIPV:0, LSPV:1, LIPV:1) (P= 0.0002). The HRV in the L group was significantly higher than that in the R group just after the CB ablation especially for the left sided PVs (L group vs. R group, total power of the HRV, median; RSPV, 11184.7 vs. 4360.0, P= 0.21; RIPV, 9044.3 vs. 2115.1, P = 0.01; LSPV, 21186.0 vs. 1314.2, P = 0.0002; LIPV 10265.9 vs. 1236.2, P = 0.0007). Conclusion: A marked increase in the HRV parameters was observed just after the CB ablation. An initial CB ablation of the right PVs decreased the change in the autonomic tone during the right PV ablation and subsequent left PV ablation. It prevented an excessive vagal response during the CB ablation and might be a safe procedure.
AB - Aims: Vagal responses such as marked bradycardia or a rapid blood pressure decrease are often observed during pulmonary vein (PV) isolation of atrial fibrillation (AF) using a cryoballoon (CB). However, the relationship between the marked vagal response and change in the heart rate variability (HRV) as a marker of the autonomic tone is not well understood. Methods and results: Fifty-four paroxysmal AF patients underwent CB ablation. The CB ablation was started from the right sided PVs in 25 patients (R group) and left sided PVs in 29 (L group). The HRV and haemodynamic status during the procedure were analysed. A vagal response was observed in 16 L group patients (61.5%) during the ablation of the different PVs (RSPV:1, RIPV:5, LSPV:15, LIPV:5), while it was observed in only 2 R group patients (9.5%) (RSPV:0, RIPV:0, LSPV:1, LIPV:1) (P= 0.0002). The HRV in the L group was significantly higher than that in the R group just after the CB ablation especially for the left sided PVs (L group vs. R group, total power of the HRV, median; RSPV, 11184.7 vs. 4360.0, P= 0.21; RIPV, 9044.3 vs. 2115.1, P = 0.01; LSPV, 21186.0 vs. 1314.2, P = 0.0002; LIPV 10265.9 vs. 1236.2, P = 0.0007). Conclusion: A marked increase in the HRV parameters was observed just after the CB ablation. An initial CB ablation of the right PVs decreased the change in the autonomic tone during the right PV ablation and subsequent left PV ablation. It prevented an excessive vagal response during the CB ablation and might be a safe procedure.
UR - http://www.scopus.com/inward/record.url?scp=85055496895&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=85055496895&partnerID=8YFLogxK
U2 - 10.1093/europace/eux225
DO - 10.1093/europace/eux225
M3 - Article
C2 - 29016780
AN - SCOPUS:85055496895
VL - 20
SP - 1259
EP - 1267
JO - Europace
JF - Europace
SN - 1099-5129
IS - 8
ER -