TY - JOUR
T1 - Association between plaque characteristics and the amount of debris captured by a filter-type distal protection device in patients with acute coronary syndrome
AU - Kitagawa, Katsuhide
AU - Amano, Tetsuya
AU - Uetani, Tadayuki
AU - Ishii, Hideki
AU - Okumura, Takahiro
AU - Suzuki, Susumu
AU - Takashima, Hiroaki
AU - Kurita, Akiyoshi
AU - Ando, Hirohiko
AU - Matsubara, Tatsuaki
AU - Murohara, Toyoaki
N1 - Publisher Copyright:
© 2017 Elsevier B.V.
PY - 2017/3/1
Y1 - 2017/3/1
N2 - Background and aims Disruption of atherosclerotic plaque and distal embolism often cause peri-procedural myocardial injury during percutaneous coronary intervention (PCI). In the present study, we evaluate the association between the characteristics of the target lesion and the amount of debris captured by the filter-type distal protection device. Methods We enrolled 120 consecutive patients with acute coronary syndrome, who underwent coronary stent implantation with a filter-type distal protection device after integrated backscatter intravascular ultrasound (IB-IVUS) analysis. The amount of debris captured by the protection filter was measured through microscopic evaluation. Results The lipid and fibrous volume evaluated with IB-IVUS was significantly correlated with the amount of the captured debris (r = 0.657, p < 0.01), (r = 0.322, p < 0.01). The lipid plaque fraction showed a positive correlation (r = 0.335, p < 0.01), while the fibrous plaque fraction was found to be inversely correlated (r = −0.375, p < 0.01) with the amount of captured debris. Multivariate regression analysis showed that lipid volume correlated independently with the amount of captured debris. Conclusion The volume of the lipid-rich plaque was associated with the amount of procedure-related debris released and captured by the filter-type distal protection device.
AB - Background and aims Disruption of atherosclerotic plaque and distal embolism often cause peri-procedural myocardial injury during percutaneous coronary intervention (PCI). In the present study, we evaluate the association between the characteristics of the target lesion and the amount of debris captured by the filter-type distal protection device. Methods We enrolled 120 consecutive patients with acute coronary syndrome, who underwent coronary stent implantation with a filter-type distal protection device after integrated backscatter intravascular ultrasound (IB-IVUS) analysis. The amount of debris captured by the protection filter was measured through microscopic evaluation. Results The lipid and fibrous volume evaluated with IB-IVUS was significantly correlated with the amount of the captured debris (r = 0.657, p < 0.01), (r = 0.322, p < 0.01). The lipid plaque fraction showed a positive correlation (r = 0.335, p < 0.01), while the fibrous plaque fraction was found to be inversely correlated (r = −0.375, p < 0.01) with the amount of captured debris. Multivariate regression analysis showed that lipid volume correlated independently with the amount of captured debris. Conclusion The volume of the lipid-rich plaque was associated with the amount of procedure-related debris released and captured by the filter-type distal protection device.
UR - http://www.scopus.com/inward/record.url?scp=85013170658&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=85013170658&partnerID=8YFLogxK
U2 - 10.1016/j.atherosclerosis.2017.02.001
DO - 10.1016/j.atherosclerosis.2017.02.001
M3 - Article
C2 - 28214424
AN - SCOPUS:85013170658
SN - 0021-9150
VL - 258
SP - 72
EP - 78
JO - Atherosclerosis
JF - Atherosclerosis
ER -