TY - JOUR
T1 - Atrial Fibrillation Detection and Ischemic Stroke Recurrence in Cryptogenic Stroke
T2 - A Retrospective, Multicenter, Observational Study
AU - CRYPTON-ICM Registry Investigators
AU - Todo, Kenichi
AU - Okazaki, Shuhei
AU - Doijiri, Ryosuke
AU - Yamazaki, Hidekazu
AU - Sonoda, Kazutaka
AU - Koge, Junpei
AU - Iwata, Tomonori
AU - Ueno, Yuji
AU - Yamagami, Hiroshi
AU - Kimura, Naoto
AU - Morimoto, Masafumi
AU - Kondo, Daisuke
AU - Koga, Masatoshi
AU - Nagata, Eiichiro
AU - Miyamoto, Nobukazu
AU - Kimura, Yoko
AU - Gon, Yasufumi
AU - Sasaki, Tsutomu
AU - Mochizuki, Hideki
N1 - Publisher Copyright:
© 2024 The Authors. Published on behalf of the American Heart Association, Inc., by Wiley.
PY - 2024
Y1 - 2024
N2 - BACKGROUND: Atrial fibrillation (AF) is known to be a strong risk factor for stroke. However, the risk of stroke recurrence in patients with cryptogenic stroke with AF detected after stroke by an insertable cardiac monitor (ICM) is not well known. We sought to evaluate the risk of ischemic stroke recurrence in patients with cryptogenic stroke with and without ICM-detected AF. METHODS AND RESULTS: We retrospectively reviewed patients with cryptogenic stroke who underwent ICM implantation at 8 stroke centers in Japan. Cox regression models were developed using landmark analysis and time-dependent analysis. We set the target sample size at 300 patients based on our estimate of the annualized incidence of ischemic stroke recurrence to be 3% in patients without AF detection and 9% in patients with AF detection. Of the 370 patients, 121 were found to have AF, and 110 received anticoagulation therapy after AF detection. The incidence of ischemic stroke recurrence was 4.0% in 249 patients without AF detection and 5.8% in 121 patients with AF detection (P=0.45). In a landmark analysis, the risk of ischemic stroke recurrence was not higher in patients with AF detected ≤90 days than in those without (hazard ratio, 1.47 [95% CI, 0.41–5.28]). In a time-dependent analysis, the risk of ischemic stroke recurrence did not increase after AF detection (hazard ratio, 1.77 [95% CI, 0.70–4.47]). CONCLUSIONS: The risk of ischemic stroke recurrence in patients with cryptogenic stroke with ICM-detected AF, 90% of whom were subsequently anticoagulated, was not higher than in those without ICM-detected AF.
AB - BACKGROUND: Atrial fibrillation (AF) is known to be a strong risk factor for stroke. However, the risk of stroke recurrence in patients with cryptogenic stroke with AF detected after stroke by an insertable cardiac monitor (ICM) is not well known. We sought to evaluate the risk of ischemic stroke recurrence in patients with cryptogenic stroke with and without ICM-detected AF. METHODS AND RESULTS: We retrospectively reviewed patients with cryptogenic stroke who underwent ICM implantation at 8 stroke centers in Japan. Cox regression models were developed using landmark analysis and time-dependent analysis. We set the target sample size at 300 patients based on our estimate of the annualized incidence of ischemic stroke recurrence to be 3% in patients without AF detection and 9% in patients with AF detection. Of the 370 patients, 121 were found to have AF, and 110 received anticoagulation therapy after AF detection. The incidence of ischemic stroke recurrence was 4.0% in 249 patients without AF detection and 5.8% in 121 patients with AF detection (P=0.45). In a landmark analysis, the risk of ischemic stroke recurrence was not higher in patients with AF detected ≤90 days than in those without (hazard ratio, 1.47 [95% CI, 0.41–5.28]). In a time-dependent analysis, the risk of ischemic stroke recurrence did not increase after AF detection (hazard ratio, 1.77 [95% CI, 0.70–4.47]). CONCLUSIONS: The risk of ischemic stroke recurrence in patients with cryptogenic stroke with ICM-detected AF, 90% of whom were subsequently anticoagulated, was not higher than in those without ICM-detected AF.
UR - http://www.scopus.com/inward/record.url?scp=85184295759&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=85184295759&partnerID=8YFLogxK
U2 - 10.1161/JAHA.123.031508
DO - 10.1161/JAHA.123.031508
M3 - Article
C2 - 38240210
AN - SCOPUS:85184295759
SN - 2047-9980
VL - 13
JO - Journal of the American Heart Association
JF - Journal of the American Heart Association
IS - 3
M1 - e031508
ER -