TY - JOUR
T1 - Carotid Plaque Diagnosis with 3-Dimensional Computed Tomography Angiography
T2 - A Comparison with Magnetic Resonance Imaging-Based Plaque Diagnosis
AU - Omi, Tatsuo
AU - Hayakawa, Motoharu
AU - Adachi, Kazuhide
AU - Ohba, Shigeo
AU - Sadato, Akiyo
AU - Hasebe, Akiko
AU - Ishihara, Takuma
AU - Nakahara, Ichiro
AU - Hirose, Yuichi
N1 - Publisher Copyright:
© Wolters Kluwer Health, Inc. All rights reserved.
PY - 2023/5/1
Y1 - 2023/5/1
N2 - Objective Although a qualitative diagnosis of plaque causing carotid stenosis has been attempted with carotid computed tomography angiography (CaCTA), no clear findings have been reported. We examined the correlation between the plaque CT values and plaque images obtained by magnetic resonance imaging to derive a qualitative diagnosis of the plaque using CaCTA. Methods Preoperative CaCTA images acquired from patients stented for carotid stenosis were retrospectively analyzed with respect to magnetization-prepared rapid acquisition with gradient echo and time-of-flight magnetic resonance angiography data. Carotid plaques in the stenosed region were quantified in terms of CT density and the plaque/muscle ratio (magnetization-prepared rapid acquisition with gradient echo), and correlations between these 2 features were determined. Plaques were classified as stable or unstable based on the plaque/muscle ratio, with the smallest plaque/muscle ratio observed among plaques positive for intraplaque hemorrhage set as the cutoff value (1.76). Results A total of 165 patients (179 plaques) were included. Perioperative complications included minor stroke (n = 3), major stroke (n = 1, fatal), and hyperperfusion (n = 2). The correlation between CT density and the plaque/muscle ratio was nonlinear (P = 0.0139) and negative (P < 0.0001). The cutoff point (1.76) corresponded to a CT density of 83 HU, supporting this value as a standard reference for plaque stability. Conclusions Computed tomography density exhibits a nonlinear (P = 0.0139) and highly negative correlation (P < 0.0001) with the plaque/muscle ratio. Our results demonstrate that plaque characteristics can be meaningfully diagnosed based on CaCTA image data.
AB - Objective Although a qualitative diagnosis of plaque causing carotid stenosis has been attempted with carotid computed tomography angiography (CaCTA), no clear findings have been reported. We examined the correlation between the plaque CT values and plaque images obtained by magnetic resonance imaging to derive a qualitative diagnosis of the plaque using CaCTA. Methods Preoperative CaCTA images acquired from patients stented for carotid stenosis were retrospectively analyzed with respect to magnetization-prepared rapid acquisition with gradient echo and time-of-flight magnetic resonance angiography data. Carotid plaques in the stenosed region were quantified in terms of CT density and the plaque/muscle ratio (magnetization-prepared rapid acquisition with gradient echo), and correlations between these 2 features were determined. Plaques were classified as stable or unstable based on the plaque/muscle ratio, with the smallest plaque/muscle ratio observed among plaques positive for intraplaque hemorrhage set as the cutoff value (1.76). Results A total of 165 patients (179 plaques) were included. Perioperative complications included minor stroke (n = 3), major stroke (n = 1, fatal), and hyperperfusion (n = 2). The correlation between CT density and the plaque/muscle ratio was nonlinear (P = 0.0139) and negative (P < 0.0001). The cutoff point (1.76) corresponded to a CT density of 83 HU, supporting this value as a standard reference for plaque stability. Conclusions Computed tomography density exhibits a nonlinear (P = 0.0139) and highly negative correlation (P < 0.0001) with the plaque/muscle ratio. Our results demonstrate that plaque characteristics can be meaningfully diagnosed based on CaCTA image data.
UR - http://www.scopus.com/inward/record.url?scp=85159391844&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=85159391844&partnerID=8YFLogxK
U2 - 10.1097/RCT.0000000000001416
DO - 10.1097/RCT.0000000000001416
M3 - Article
C2 - 36944131
AN - SCOPUS:85159391844
SN - 0363-8715
VL - 47
SP - 488
EP - 493
JO - Journal of Computer Assisted Tomography
JF - Journal of Computer Assisted Tomography
IS - 3
ER -