T1 - CenTauRz
T2 - A standardized quantification of tau PET scans
AU - Dore, Vincent
AU - Bullich, Santiago
AU - Bohorquez, Sandra Sanabria
AU - Leuzy, Antoine
AU - Shimada, Hitoshi
AU - Rowe, Christopher
AU - Bourgeat, Pierrick
AU - Lopresti, Brian J.
AU - Huang, Kun
AU - Krishnadas, Natasha
AU - Fripp, Jurgen
AU - Takado, Yuhei
AU - Stephens, Andrew W.
AU - Weimer, Robby
AU - Higuchi, Makoto
AU - Hansson, Oskar
AU - Villemagne, Victor L.
N1 - Publisher Copyright:
© 2022 the Alzheimer's Association.
PY - 2022/12
Y1 - 2022/12
N2 - Background: Over the past decade, several PET tracers were developed to visualise and quantify tau pathology in vivo. However, all these tracers have distinct off-target binding, different dynamic ranges and likely different levels of non-specific binding resulting in large variability in semiquantification. We propose to standardise the sampling and the quantification across all available tau tracers. Method: 549 participants underwent tau scans with either 18F-FTP (Cognitively Unimpaired (CU)=54/AD=14), 18F-MK6240 (CU=186/AD=89), 18F-PI2620 (CU=17/AD=21), 18F-PM-PBB3 (CU=30/AD=28), 18F-GTP1 (CU=7/AD=38) or 18F-RO948 (CU=35/AD=30). All CU individuals were Aβ- and all AD were Aβ+. The tau scans were spatially normalized using CapAIBL and the cerebellar cortex was used as reference region. We constructed a “universal” tau mask from the intersection of all the specific tau tracer masks, after subtracting AD from CU. All tau PET studies were sampled with a Mesial Temporal (MTL) and a Meta Temporal (MetaT) composites constrained by the universal mask. For each tracer and in composite, the mean and standard deviation of the Aβ- CU SUVR for each tau tracer were used to generate z-scores (CenTauRz). Result: Using a threshold of 2 CenTauRz in the MetaT regions, all tracers highly discriminated Aβ+ AD from Aβ- CU (ACC=[0.94-1], sens=[0.84-1], spec=[0.96-1]) with mean CenTauRz for the different AD cohorts ranging from 8 to 14. Lower accuracy was observed in the MTL (ACC=[0.78-1]) due to lower sensitivity in some cohorts [0.65-1] however, the specificity was similar to that in the MetaT composite (spec=[0.94,1]). Conclusion: All tracers exhibited comparably high discriminative power to separate Aβ+ AD from Aβ- CU, where AD Aβ+ displayed a consistent range of CenTauRz across tracers. However, there were some differences between cohorts. For example, different PET scanners, with different sensitivities were used. For some cohorts, scans were selected as extreme representative cases, while for others the scans were more representative of clinical settings, with AD patients at early stages (with low or negative tau scans) or with suspected hippocampal sparing subtype that likely explains the lower accuracy in the MTL for some cohorts. Further studies with larger cohorts to validate the universal mask and CenTauRz scale are ongoing.
AB - Background: Over the past decade, several PET tracers were developed to visualise and quantify tau pathology in vivo. However, all these tracers have distinct off-target binding, different dynamic ranges and likely different levels of non-specific binding resulting in large variability in semiquantification. We propose to standardise the sampling and the quantification across all available tau tracers. Method: 549 participants underwent tau scans with either 18F-FTP (Cognitively Unimpaired (CU)=54/AD=14), 18F-MK6240 (CU=186/AD=89), 18F-PI2620 (CU=17/AD=21), 18F-PM-PBB3 (CU=30/AD=28), 18F-GTP1 (CU=7/AD=38) or 18F-RO948 (CU=35/AD=30). All CU individuals were Aβ- and all AD were Aβ+. The tau scans were spatially normalized using CapAIBL and the cerebellar cortex was used as reference region. We constructed a “universal” tau mask from the intersection of all the specific tau tracer masks, after subtracting AD from CU. All tau PET studies were sampled with a Mesial Temporal (MTL) and a Meta Temporal (MetaT) composites constrained by the universal mask. For each tracer and in composite, the mean and standard deviation of the Aβ- CU SUVR for each tau tracer were used to generate z-scores (CenTauRz). Result: Using a threshold of 2 CenTauRz in the MetaT regions, all tracers highly discriminated Aβ+ AD from Aβ- CU (ACC=[0.94-1], sens=[0.84-1], spec=[0.96-1]) with mean CenTauRz for the different AD cohorts ranging from 8 to 14. Lower accuracy was observed in the MTL (ACC=[0.78-1]) due to lower sensitivity in some cohorts [0.65-1] however, the specificity was similar to that in the MetaT composite (spec=[0.94,1]). Conclusion: All tracers exhibited comparably high discriminative power to separate Aβ+ AD from Aβ- CU, where AD Aβ+ displayed a consistent range of CenTauRz across tracers. However, there were some differences between cohorts. For example, different PET scanners, with different sensitivities were used. For some cohorts, scans were selected as extreme representative cases, while for others the scans were more representative of clinical settings, with AD patients at early stages (with low or negative tau scans) or with suspected hippocampal sparing subtype that likely explains the lower accuracy in the MTL for some cohorts. Further studies with larger cohorts to validate the universal mask and CenTauRz scale are ongoing.
UR - http://www.scopus.com/inward/record.url?scp=85144343245&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=85144343245&partnerID=8YFLogxK
U2 - 10.1002/alz.061177
DO - 10.1002/alz.061177
M3 - Comment/debate
AN - SCOPUS:85144343245
SN - 1552-5260
VL - 18
JO - Alzheimer's and Dementia
JF - Alzheimer's and Dementia
IS - S1
M1 - e061177
ER -