Clinical experience with a new hip-knee-ankle-foot orthotic system using a medial single hip joint for paraplegic standing and walking

Eiichi Saitoh, Toru Suzuki, Shigeru Sonoda, Junko Fujitani, Yutaka Tomita, Naoichi Chino

Research output: Contribution to journalArticle

49 Citations (Scopus)

Abstract

The Walkabout® is a new hip-knee-ankle-foot orthotic (HKAFO) system with a medial single hip joint (MSH-KAFO) invented by S. McKay in 1992. Compared with other HKAFO systems, the hip joint part is compact and removable, so it has distinguishable, real merits: ease in donning and doffing the device, compatibility with a wheelchair, and cosmesis. We clinically tested five patients, paraplegic because of spinal cord injury, using the MSH-KAFO system. All were males, aged 26-36 yr old. Their functional levels were L-1 (2 cases), T-10 (2 cases), and T-5 (1 case). All patients could stand stably without crutches and walk in parallel bars immediately the first time they wore the braces. After a few hours of crutch-walking exercises, all could walk independently with Lofstrand crutches. Their walking velocities ranged from 10 to 37.5 (mean, 19.9) m/min at the follow-up points (mean, 7.1 mo). With four cases, we measured oxygen uptake for predictions of energy consumption. At comfortable walking, predicted energy consumptions were from 1.31 to 3.89 (mean, 2.75) METs. Compared with the data in literature, these seemed to be at the same level with normal walking and lower than the KAFOs walking level. Our results suggest that MSH-KAFO is a very convenient standing and walking device for paraplegics and is compatible with wheelchair use.

Original languageEnglish
Pages (from-to)198-203
Number of pages6
JournalAmerican Journal of Physical Medicine and Rehabilitation
Volume75
Issue number3
DOIs
Publication statusPublished - 01-05-1996

Fingerprint

Hip Joint
Ankle
Walking
Hip
Foot
Knee
Crutches
Melanocyte-Stimulating Hormones
Wheelchairs
Equipment and Supplies
Braces
Spinal Cord Injuries
Exercise
Oxygen

All Science Journal Classification (ASJC) codes

  • Physical Therapy, Sports Therapy and Rehabilitation
  • Rehabilitation

Cite this

@article{2c798971531b4d788f1d744bd030a1f8,
title = "Clinical experience with a new hip-knee-ankle-foot orthotic system using a medial single hip joint for paraplegic standing and walking",
abstract = "The Walkabout{\circledR} is a new hip-knee-ankle-foot orthotic (HKAFO) system with a medial single hip joint (MSH-KAFO) invented by S. McKay in 1992. Compared with other HKAFO systems, the hip joint part is compact and removable, so it has distinguishable, real merits: ease in donning and doffing the device, compatibility with a wheelchair, and cosmesis. We clinically tested five patients, paraplegic because of spinal cord injury, using the MSH-KAFO system. All were males, aged 26-36 yr old. Their functional levels were L-1 (2 cases), T-10 (2 cases), and T-5 (1 case). All patients could stand stably without crutches and walk in parallel bars immediately the first time they wore the braces. After a few hours of crutch-walking exercises, all could walk independently with Lofstrand crutches. Their walking velocities ranged from 10 to 37.5 (mean, 19.9) m/min at the follow-up points (mean, 7.1 mo). With four cases, we measured oxygen uptake for predictions of energy consumption. At comfortable walking, predicted energy consumptions were from 1.31 to 3.89 (mean, 2.75) METs. Compared with the data in literature, these seemed to be at the same level with normal walking and lower than the KAFOs walking level. Our results suggest that MSH-KAFO is a very convenient standing and walking device for paraplegics and is compatible with wheelchair use.",
author = "Eiichi Saitoh and Toru Suzuki and Shigeru Sonoda and Junko Fujitani and Yutaka Tomita and Naoichi Chino",
year = "1996",
month = "5",
day = "1",
doi = "10.1097/00002060-199605000-00010",
language = "English",
volume = "75",
pages = "198--203",
journal = "American Journal of Physical Medicine and Rehabilitation",
issn = "0894-9115",
publisher = "Lippincott Williams and Wilkins",
number = "3",

}

Clinical experience with a new hip-knee-ankle-foot orthotic system using a medial single hip joint for paraplegic standing and walking. / Saitoh, Eiichi; Suzuki, Toru; Sonoda, Shigeru; Fujitani, Junko; Tomita, Yutaka; Chino, Naoichi.

In: American Journal of Physical Medicine and Rehabilitation, Vol. 75, No. 3, 01.05.1996, p. 198-203.

Research output: Contribution to journalArticle

TY - JOUR

T1 - Clinical experience with a new hip-knee-ankle-foot orthotic system using a medial single hip joint for paraplegic standing and walking

AU - Saitoh, Eiichi

AU - Suzuki, Toru

AU - Sonoda, Shigeru

AU - Fujitani, Junko

AU - Tomita, Yutaka

AU - Chino, Naoichi

PY - 1996/5/1

Y1 - 1996/5/1

N2 - The Walkabout® is a new hip-knee-ankle-foot orthotic (HKAFO) system with a medial single hip joint (MSH-KAFO) invented by S. McKay in 1992. Compared with other HKAFO systems, the hip joint part is compact and removable, so it has distinguishable, real merits: ease in donning and doffing the device, compatibility with a wheelchair, and cosmesis. We clinically tested five patients, paraplegic because of spinal cord injury, using the MSH-KAFO system. All were males, aged 26-36 yr old. Their functional levels were L-1 (2 cases), T-10 (2 cases), and T-5 (1 case). All patients could stand stably without crutches and walk in parallel bars immediately the first time they wore the braces. After a few hours of crutch-walking exercises, all could walk independently with Lofstrand crutches. Their walking velocities ranged from 10 to 37.5 (mean, 19.9) m/min at the follow-up points (mean, 7.1 mo). With four cases, we measured oxygen uptake for predictions of energy consumption. At comfortable walking, predicted energy consumptions were from 1.31 to 3.89 (mean, 2.75) METs. Compared with the data in literature, these seemed to be at the same level with normal walking and lower than the KAFOs walking level. Our results suggest that MSH-KAFO is a very convenient standing and walking device for paraplegics and is compatible with wheelchair use.

AB - The Walkabout® is a new hip-knee-ankle-foot orthotic (HKAFO) system with a medial single hip joint (MSH-KAFO) invented by S. McKay in 1992. Compared with other HKAFO systems, the hip joint part is compact and removable, so it has distinguishable, real merits: ease in donning and doffing the device, compatibility with a wheelchair, and cosmesis. We clinically tested five patients, paraplegic because of spinal cord injury, using the MSH-KAFO system. All were males, aged 26-36 yr old. Their functional levels were L-1 (2 cases), T-10 (2 cases), and T-5 (1 case). All patients could stand stably without crutches and walk in parallel bars immediately the first time they wore the braces. After a few hours of crutch-walking exercises, all could walk independently with Lofstrand crutches. Their walking velocities ranged from 10 to 37.5 (mean, 19.9) m/min at the follow-up points (mean, 7.1 mo). With four cases, we measured oxygen uptake for predictions of energy consumption. At comfortable walking, predicted energy consumptions were from 1.31 to 3.89 (mean, 2.75) METs. Compared with the data in literature, these seemed to be at the same level with normal walking and lower than the KAFOs walking level. Our results suggest that MSH-KAFO is a very convenient standing and walking device for paraplegics and is compatible with wheelchair use.

UR - http://www.scopus.com/inward/record.url?scp=0030152820&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=0030152820&partnerID=8YFLogxK

U2 - 10.1097/00002060-199605000-00010

DO - 10.1097/00002060-199605000-00010

M3 - Article

C2 - 8663927

AN - SCOPUS:0030152820

VL - 75

SP - 198

EP - 203

JO - American Journal of Physical Medicine and Rehabilitation

JF - American Journal of Physical Medicine and Rehabilitation

SN - 0894-9115

IS - 3

ER -