TY - JOUR
T1 - Clinical impact of kidney function on presepsin levels
AU - Nagata, Takanobu
AU - Yasuda, Yoshinari
AU - Ando, Masahiko
AU - Abe, Tomoko
AU - Katsuno, Takayuki
AU - Kato, Sawako
AU - Tsuboi, Naotake
AU - Matsuo, Seiichi
AU - Maruyama, Shoichi
N1 - Publisher Copyright:
© 2015 Nagata et al. This is an open access article distributed under the terms of the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are credited.
PY - 2015/6/1
Y1 - 2015/6/1
N2 - Objective: Presepsin is highlighted as a diagnostic and prognostic marker of sepsis. Little information is available regarding the accurate association between presepsin levels and the degree of kidney function. We analyzed presepsin levels in patients with a glomerular filtration rate (GFR) in the categories G1 to G5, evaluated via inulin renal clearance test, and receiving hemodialysis (HD). Methods: Patients who were not receiving HD were included if they had undergone inulin renal clearance measurements for the accurate measurement of GFR (measured GFR), and patients who were receiving hemodialysis (HD) were included if they had anuria. Exclusion criteria were infection, cancer, liver disease, autoimmune disorders, or steroid or immunosuppressant use. GFR category was defined as follows; G1: GFR ≥ 90 ml/min/1.73m2, G2: GFR = 60 to 90 ml/min/1.73m2, G3: GFR = 30 to 60 ml/min/1.73m2, G4: GFR = 15 to 30 ml/min/1.73m2, G5: GFR ≤ 15 ml/min/1.73m2. Results: Seventy-one patients were included. The median (IQR) presepsin values of patients in each GFR category were as follows: G1 + G2: 69.8 (60.8-85.9) pg/ml; G3: 107.0 (68.7-150.0) pg/ml; G4: 171.0 (117.0-200.0) pg/ml; G5: 251.0 (213.0-297.5) pg/ml; and HD: 1160.0 (1070.0-1400.0) pg/ml. The log-transformed presepsin values, excluding patients receiving HD, inversely correlated with the measured GFR (Pearson's correlation coefficient = -0.687, P < 0.001). The multivariate analysis revealed that measured GFR and hemoglobin levels significantly correlated with elevated presepsin levels. Conclusion: Presepsin levels were markedly high in patients receiving HD, similar to values seen in patients with severe sepsis or septic shock. In patients who were not receiving HD, presepsin levels increased as GFR decreased. Thus, the evaluation of presepsin levels in patients with chronic kidney disease requires further consideration, and a different cutoff value is needed for diagnosing sepsis in such patients.
AB - Objective: Presepsin is highlighted as a diagnostic and prognostic marker of sepsis. Little information is available regarding the accurate association between presepsin levels and the degree of kidney function. We analyzed presepsin levels in patients with a glomerular filtration rate (GFR) in the categories G1 to G5, evaluated via inulin renal clearance test, and receiving hemodialysis (HD). Methods: Patients who were not receiving HD were included if they had undergone inulin renal clearance measurements for the accurate measurement of GFR (measured GFR), and patients who were receiving hemodialysis (HD) were included if they had anuria. Exclusion criteria were infection, cancer, liver disease, autoimmune disorders, or steroid or immunosuppressant use. GFR category was defined as follows; G1: GFR ≥ 90 ml/min/1.73m2, G2: GFR = 60 to 90 ml/min/1.73m2, G3: GFR = 30 to 60 ml/min/1.73m2, G4: GFR = 15 to 30 ml/min/1.73m2, G5: GFR ≤ 15 ml/min/1.73m2. Results: Seventy-one patients were included. The median (IQR) presepsin values of patients in each GFR category were as follows: G1 + G2: 69.8 (60.8-85.9) pg/ml; G3: 107.0 (68.7-150.0) pg/ml; G4: 171.0 (117.0-200.0) pg/ml; G5: 251.0 (213.0-297.5) pg/ml; and HD: 1160.0 (1070.0-1400.0) pg/ml. The log-transformed presepsin values, excluding patients receiving HD, inversely correlated with the measured GFR (Pearson's correlation coefficient = -0.687, P < 0.001). The multivariate analysis revealed that measured GFR and hemoglobin levels significantly correlated with elevated presepsin levels. Conclusion: Presepsin levels were markedly high in patients receiving HD, similar to values seen in patients with severe sepsis or septic shock. In patients who were not receiving HD, presepsin levels increased as GFR decreased. Thus, the evaluation of presepsin levels in patients with chronic kidney disease requires further consideration, and a different cutoff value is needed for diagnosing sepsis in such patients.
UR - http://www.scopus.com/inward/record.url?scp=84934976268&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=84934976268&partnerID=8YFLogxK
U2 - 10.1371/journal.pone.0129159
DO - 10.1371/journal.pone.0129159
M3 - Article
C2 - 26030716
AN - SCOPUS:84934976268
SN - 1932-6203
VL - 10
JO - PloS one
JF - PloS one
IS - 6
M1 - e0129159
ER -