Comparative evaluation of absorbed doses in silver wedge-filter-based chest CT versus chest radiography: A Monte Carlo study

Yusei Nishihara, Masanao Kobayashi, Akari Satake, Tsuzuki Tadasuke, Rei Ito, Tomonobu Haba, Shigeki Kobayashi

Research output: Contribution to journalArticlepeer-review

Abstract

In the silver (Ag) wedge-filter-fitted computed tomography (CT) scanner, we estimated organ doses during chest CT examinations and chest radiography to assess the Ag-filter-based dose reduction in six scan protocols for chest CT: three conventional protocols with standard filters (clinical standard, low-dose, and ultra-low-dose) and three corresponding Ag-filter-based protocols; the tube current was adjusted to maintain similar standard deviations (SD) and two protocols for chest radiography: posteroanterior (PA) projection (medical checkups) and posteroanterior with right-left (PA + RL) projection (clinical protocols). Using the Monte Carlo simulation software (ImpactMC), we estimated absorbed doses by simulating photon transport in computational phantoms (adult males and females) based on average values for organ doses (lungs, breast tissue, heart, stomach, and liver) and the maximum value for the skin dose. Despite similar SD, the organ and tissue doses in the Ag filter-based ultra-low-dose chest CT protocol (vs. no-Ag filter) were lower for females: skin (39.6 %), lung (17.4 %), breast tissue (20.1 %), heart (16.5 %), stomach (14.4 %), and liver (16.7 %), with similar dose reductions across other scan protocols. In the ultra-low-dose Ag-filter-based chest CT protocol, the absorbed doses resembled those of PA + RL radiography (clinical protocol). During chest CT examinations, the Ag filter-based effective reduction of the radiation dose conferred a potentially significant impact on the risk–benefit balance in CT-based lung cancer screening; this potentially influences the screening targets and overall effectiveness. By balancing radiation risk and diagnostic benefits, the Ag filter facilitates a paradigm shift from radiography to ultra-low-dose CT examinations in conventional diagnosis and follow-up.

Original languageEnglish
Article number113274
JournalRadiation Physics and Chemistry
Volume239
DOIs
Publication statusPublished - 02-2026

All Science Journal Classification (ASJC) codes

  • Radiation

Fingerprint

Dive into the research topics of 'Comparative evaluation of absorbed doses in silver wedge-filter-based chest CT versus chest radiography: A Monte Carlo study'. Together they form a unique fingerprint.

Cite this