TY - JOUR
T1 - Comparison of biomechanical assessment between upright and supine inspiratory-expiratory area-detector CT in progressive pulmonary fibrosis
AU - Ohno, Yoshiharu
AU - Aoyagi, Kota
AU - Ozawa, Yoshiyuki
AU - Nomura, Masahiko
AU - Kimata, Hirona
AU - Ito, Yuya
AU - Fujii, Kenji
AU - Ueda, Takahiro
AU - Araoka, Junichiro
AU - Akino, Naruomi
AU - Yoshikawa, Takeshi
AU - Takenaka, Daisuke
AU - Endo, Masahiko
AU - Hoshikawa, Yasushi
AU - Yasuoka, Hidekata
AU - Horiguchi, Tomoya
AU - Goto, Yasuhiro
AU - Hashimoto, Naozumi
AU - Imaizumi, Kazuyoshi
N1 - Publisher Copyright:
© The Author(s) 2026.
PY - 2026/12
Y1 - 2026/12
N2 - Background: We compared the capabilities of quantitatively assessed paired inspiratory-expiratory area-detector computed tomography (ADCT) for pulmonary functional loss and disease severity evaluations between upright and supine ADCT in matched progressive pulmonary fibrosis (PPF) patients. Materials and methods: This retrospective cohort consisted of age-, sex-, and underlying disease-matched patients with PPF who underwent paired inspiratory-expiratory CT on upright ADCT (n = 40) and supine ADCT (n = 40), pulmonary function tests, and disease severity assessment. Based on CT data, the absolute values of the logarithm of the Jacobian determinant and warp-field magnitude of the whole lung and all lobes were calculated. Stepwise regression analyses were performed. Results: On supine ADCT, both indices of the left lower lobe (LLL) were the first and only steps for pulmonary function test results and CT-assessed disease severity (absolute value of the logarithm of the Jacobian determinant: 0.139 ≤ r2 ≤ 0.175, 0.007 ≤ p ≤ 0.018; absolute value of the warp-field magnitude: 0.371 ≤ r2 ≤ 0.447, p < 0.001). However, on upright ADCT, both indices indicated that LLL was the first step and the right lower lobe was the second step for pulmonary function test results and CT-assessed disease severity (0.503 ≤ r2 ≤ 0.674, p < 0.001 or 0.000 < p ≤ 0.006 and 0.474 ≤ r2 ≤ 0.652, 0.002 ≤ p ≤ 0.045, respectively). Conclusion: Upright ADCT has equal to or better potential than supine ADCT for detecting pulmonary functional loss and evaluating disease severity when paired inspiratory-expiratory ADCT is applied in PPF patients. Relevance statement: Upright ADCT has superior potential to supine ADCT for pulmonary functional loss and disease severity evaluations when paired inspiratory-expiratory ADCT is performed in patients with progressive pulmonary fibrosis (PPF). Key Points: Matched progressive pulmonary fibrosis patients compared functional loss and disease severity evaluations between inspiratory-expiratory upright and supine area-detector CT. Clinical parameters demonstrated better correlations with upright than with supine inspiratory-expiratory area-detector CT. Warp-field magnitude showed better correlations with disease severities than the logarithm of the Jacobian determinant on each area-detector CT.
AB - Background: We compared the capabilities of quantitatively assessed paired inspiratory-expiratory area-detector computed tomography (ADCT) for pulmonary functional loss and disease severity evaluations between upright and supine ADCT in matched progressive pulmonary fibrosis (PPF) patients. Materials and methods: This retrospective cohort consisted of age-, sex-, and underlying disease-matched patients with PPF who underwent paired inspiratory-expiratory CT on upright ADCT (n = 40) and supine ADCT (n = 40), pulmonary function tests, and disease severity assessment. Based on CT data, the absolute values of the logarithm of the Jacobian determinant and warp-field magnitude of the whole lung and all lobes were calculated. Stepwise regression analyses were performed. Results: On supine ADCT, both indices of the left lower lobe (LLL) were the first and only steps for pulmonary function test results and CT-assessed disease severity (absolute value of the logarithm of the Jacobian determinant: 0.139 ≤ r2 ≤ 0.175, 0.007 ≤ p ≤ 0.018; absolute value of the warp-field magnitude: 0.371 ≤ r2 ≤ 0.447, p < 0.001). However, on upright ADCT, both indices indicated that LLL was the first step and the right lower lobe was the second step for pulmonary function test results and CT-assessed disease severity (0.503 ≤ r2 ≤ 0.674, p < 0.001 or 0.000 < p ≤ 0.006 and 0.474 ≤ r2 ≤ 0.652, 0.002 ≤ p ≤ 0.045, respectively). Conclusion: Upright ADCT has equal to or better potential than supine ADCT for detecting pulmonary functional loss and evaluating disease severity when paired inspiratory-expiratory ADCT is applied in PPF patients. Relevance statement: Upright ADCT has superior potential to supine ADCT for pulmonary functional loss and disease severity evaluations when paired inspiratory-expiratory ADCT is performed in patients with progressive pulmonary fibrosis (PPF). Key Points: Matched progressive pulmonary fibrosis patients compared functional loss and disease severity evaluations between inspiratory-expiratory upright and supine area-detector CT. Clinical parameters demonstrated better correlations with upright than with supine inspiratory-expiratory area-detector CT. Warp-field magnitude showed better correlations with disease severities than the logarithm of the Jacobian determinant on each area-detector CT.
KW - Biomechanical phenomena
KW - Lung diseases (interstitial)
KW - Pulmonary fibrosis
KW - Respiratory function tests
KW - Tomography (x-ray computed)
UR - https://www.scopus.com/pages/publications/105034704443
UR - https://www.scopus.com/pages/publications/105034704443#tab=citedBy
U2 - 10.1186/s41747-026-00698-y
DO - 10.1186/s41747-026-00698-y
M3 - Article
C2 - 41915313
AN - SCOPUS:105034704443
SN - 2509-9280
VL - 10
JO - European radiology experimental
JF - European radiology experimental
IS - 1
M1 - 37
ER -