TY - JOUR
T1 - Comparison of urethral diameters for calculating the urethral dose after permanent prostate brachytherapy
AU - Tanaka, Osamu
AU - Hayashi, Shinya
AU - Matsuo, Masayuki
AU - Nakano, Masahiro
AU - Kubota, Yasuaki
AU - Maeda, Sunaho
AU - Ohtakara, Kazuhiro
AU - Deguchi, Takashi
AU - Hoshi, Hiroaki
PY - 2007/8
Y1 - 2007/8
N2 - Purpose. No studies have yet evaluated the effects of a dosimetric analysis for different urethral volumes. We therefore evaluated the effects of a dosimetric analysis to determine the different urethral volumes. Methods. This study was based on computed tomography/magnetic resonance imaging (CT/MRI) combined findings in 30 patients who had undergone prostate brachytherapy. Postimplant CT/MRI scans were performed 30 days after the implant. The urethra was contoured based on its diameter (8, 6, 4, 2, and 0 mm). The total urethral volume-in cubic centimeters [UrV150/200(cc)] and percent (UrV150%/200%), of the urethra receiving 150% or 200% of the prescribed dose-and the doses (UrD90/30/5) in Grays to 90%, 30%, and 5% of the urethral volume were measured based on the urethral diameters. Results. The UrV150(cc) and UrD30 were statistically different between the of 8-, 6-, 4-, 2-, and 0-mm diameters, whereas the UrD5 was statistically different only between the 8-, 6-, and 4-mm diameters. Especially for UrD5, there was an approximately 40-Gy difference between the mean values for the 8- and 0-mm diameters. Conclusion. We recommend that the urethra should be contoured as a 4- to 6-mm diameter circle or one side of a triangle of 5-7 mm. By standardizing the urethral diameter, the urethral dose will be less affected by the total urethral volume.
AB - Purpose. No studies have yet evaluated the effects of a dosimetric analysis for different urethral volumes. We therefore evaluated the effects of a dosimetric analysis to determine the different urethral volumes. Methods. This study was based on computed tomography/magnetic resonance imaging (CT/MRI) combined findings in 30 patients who had undergone prostate brachytherapy. Postimplant CT/MRI scans were performed 30 days after the implant. The urethra was contoured based on its diameter (8, 6, 4, 2, and 0 mm). The total urethral volume-in cubic centimeters [UrV150/200(cc)] and percent (UrV150%/200%), of the urethra receiving 150% or 200% of the prescribed dose-and the doses (UrD90/30/5) in Grays to 90%, 30%, and 5% of the urethral volume were measured based on the urethral diameters. Results. The UrV150(cc) and UrD30 were statistically different between the of 8-, 6-, 4-, 2-, and 0-mm diameters, whereas the UrD5 was statistically different only between the 8-, 6-, and 4-mm diameters. Especially for UrD5, there was an approximately 40-Gy difference between the mean values for the 8- and 0-mm diameters. Conclusion. We recommend that the urethra should be contoured as a 4- to 6-mm diameter circle or one side of a triangle of 5-7 mm. By standardizing the urethral diameter, the urethral dose will be less affected by the total urethral volume.
UR - http://www.scopus.com/inward/record.url?scp=38449122439&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=38449122439&partnerID=8YFLogxK
U2 - 10.1007/s11604-007-0146-2
DO - 10.1007/s11604-007-0146-2
M3 - Article
C2 - 17705002
AN - SCOPUS:38449122439
SN - 0288-2043
VL - 25
SP - 329
EP - 334
JO - Radiation Medicine - Medical Imaging and Radiation Oncology
JF - Radiation Medicine - Medical Imaging and Radiation Oncology
IS - 7
ER -