TY - JOUR
T1 - Compressed sensing with deep learning reconstruction
T2 - Improving capability of gadolinium-EOB-enhanced 3D T1WI
AU - Nagata, Hiroyuki
AU - Ohno, Yoshiharu
AU - Yoshikawa, Takeshi
AU - Yamamoto, Kaori
AU - Shinohara, Maiko
AU - Ikedo, Masato
AU - Yui, Masao
AU - Matsuyama, Takahiro
AU - Takahashi, Tomoki
AU - Bando, Shuji
AU - Furuta, Minami
AU - Ueda, Takahiro
AU - Ozawa, Yoshiyuki
AU - Toyama, Hiroshi
N1 - Publisher Copyright:
© 2024 Elsevier Inc.
PY - 2024/5
Y1 - 2024/5
N2 - Purpose: The purpose of this study was to determine the utility of compressed sensing (CS) with deep learning reconstruction (DLR) for improving spatial resolution, image quality and focal liver lesion detection on high-resolution contrast-enhanced T1-weighted imaging (HR-CE-T1WI) obtained by CS with DLR as compared with conventional CE-T1WI with parallel imaging (PI). Methods: Seventy-seven participants with focal liver lesions underwent conventional CE-T1WI with PI and HR-CE-T1WI, surgical resection, transarterial chemoembolization, and radiofrequency ablation, followed by histopathological or >2-year follow-up examinations in our hospital. Signal-to-noise ratios (SNRs) of liver, spleen and kidney were calculated for each patient, after which each SNR was compared by means of paired t-test. To compare focal lesion detection capabilities of the two methods, a 5-point visual scoring system was adopted for a per lesion basis analysis. Jackknife free-response receiver operating characteristic (JAFROC) analysis was then performed, while sensitivity and false positive rates (/data set) for consensus assessment of the two methods were also compared by using McNemar's test or the signed rank test. Results: Each SNR of HR-CE-T1WI was significantly higher than that of conventional CE-T1WI with PI (p < 0.05). Sensitivities for consensus assessment showed that HR-CE-MRI had significantly higher sensitivity than conventional CE-T1WI with PI (p = 0.004). Moreover, there were significantly fewer FP/cases for HR-CE-T1WI than for conventional CE-T1WI with PI (p = 0.04). Conclusion: CS with DLR are useful for improving spatial resolution, image quality and focal liver lesion detection capability of Gd-EOB-DTPA enhanced 3D T1WI without any need for longer breath-holding time.
AB - Purpose: The purpose of this study was to determine the utility of compressed sensing (CS) with deep learning reconstruction (DLR) for improving spatial resolution, image quality and focal liver lesion detection on high-resolution contrast-enhanced T1-weighted imaging (HR-CE-T1WI) obtained by CS with DLR as compared with conventional CE-T1WI with parallel imaging (PI). Methods: Seventy-seven participants with focal liver lesions underwent conventional CE-T1WI with PI and HR-CE-T1WI, surgical resection, transarterial chemoembolization, and radiofrequency ablation, followed by histopathological or >2-year follow-up examinations in our hospital. Signal-to-noise ratios (SNRs) of liver, spleen and kidney were calculated for each patient, after which each SNR was compared by means of paired t-test. To compare focal lesion detection capabilities of the two methods, a 5-point visual scoring system was adopted for a per lesion basis analysis. Jackknife free-response receiver operating characteristic (JAFROC) analysis was then performed, while sensitivity and false positive rates (/data set) for consensus assessment of the two methods were also compared by using McNemar's test or the signed rank test. Results: Each SNR of HR-CE-T1WI was significantly higher than that of conventional CE-T1WI with PI (p < 0.05). Sensitivities for consensus assessment showed that HR-CE-MRI had significantly higher sensitivity than conventional CE-T1WI with PI (p = 0.004). Moreover, there were significantly fewer FP/cases for HR-CE-T1WI than for conventional CE-T1WI with PI (p = 0.04). Conclusion: CS with DLR are useful for improving spatial resolution, image quality and focal liver lesion detection capability of Gd-EOB-DTPA enhanced 3D T1WI without any need for longer breath-holding time.
KW - Compressed sensing
KW - Contrast media
KW - Deep learning reconstruction
KW - Liver
KW - MRI
UR - http://www.scopus.com/inward/record.url?scp=85184575317&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=85184575317&partnerID=8YFLogxK
U2 - 10.1016/j.mri.2024.01.015
DO - 10.1016/j.mri.2024.01.015
M3 - Article
C2 - 38309378
AN - SCOPUS:85184575317
SN - 0730-725X
VL - 108
SP - 67
EP - 76
JO - Magnetic Resonance Imaging
JF - Magnetic Resonance Imaging
ER -