Continuous positive airway pressure improves daytime baroreflex sensitivity and nitric oxide production in patients with moderate to severe obstructive sleep apnea syndrome

Akiko Noda, Seiichi Nakata, Yasuo Koike, Seiko Miyate, Kiyoyuki Kitaichi, Takao Nishizawa, Kohzo Nagata, Fumihiko Yasuma, Toyoaki Murohara, Mitsuhiro Yokota

Research output: Contribution to journalArticlepeer-review

95 Citations (Scopus)

Abstract

Individuals with obstructive sleep apnea syndrome (OSAS) are at high risk for cardiovascular morbidity and mortality. The effects of OSAS severity and nocturnal continuous positive airway pressure (CPAP) on day-time baroreflex sensitivity (BRS) and nitric oxide (NO) production were investigated in OSAS patients. Fifty-one consecutive males with OSAS and 29 age-matched healthy men underwent the Valsalva test and standard polysomnography. Patients with an apnea-hypopnea index (AHI) of ≥20 episodes per hour were randomized to receive CPAP treatment for 3 months (n=14) or no such treatment (n=19). The BRS index measured from the overshoot phase (phase IV) of the Valsalva maneuver and plasma NO concentration were significantly lower, whereas the AHI, oxygen desaturation time, arousal index, percentage of sleep stage 1, and systolic blood pressure were significantly greater, in patients with an AHI of ≥2O/h than in those with an AHI of <20/h or in controls. The 24-h urinary excretion of norepinephrine was significantly reduced and the plasma NO concentration was significantly increased after one night of CPAP. The BRS index for phase IV and the Valsalva ratio were significantly increased in the CPAP group after the 3-month treatment period but remained unchanged in the non-CPAP group of OSAS patients. The daytime BRS index and NO production were thus inversely related to the severity of OSAS, and successful CPAP treatment improved these parameters in patients with moderate to severe OSAS. CPAP may therefore reduce the risk of cardiovascular complications due to endothelial dysfunction or increased sympathetic activity.

Original languageEnglish
Pages (from-to)669-676
Number of pages8
JournalHypertension Research
Volume30
Issue number8
DOIs
Publication statusPublished - 08-2007
Externally publishedYes

All Science Journal Classification (ASJC) codes

  • Internal Medicine
  • Physiology
  • Cardiology and Cardiovascular Medicine

Fingerprint

Dive into the research topics of 'Continuous positive airway pressure improves daytime baroreflex sensitivity and nitric oxide production in patients with moderate to severe obstructive sleep apnea syndrome'. Together they form a unique fingerprint.

Cite this