Current topics in glycemic control by wearable artificial pancreas or bedside artificial pancreas with closed-loop system

Kazuhiro Hanazaki, Masaya Munekage, Hiroyuki Kitagawa, Tomoaki Yatabe, Eri Munekage, Mai Shiga, Hiromichi Maeda, Tsutomu Namikawa

Research output: Contribution to journalReview articlepeer-review

18 Citations (Scopus)

Abstract

The incidence of diabetes is increasing at an unprecedented pace and has become a serious health concern worldwide during the last two decades. Despite this, adequate glycemic control using an artificial pancreas has not been established, although the 21st century has seen rapid developments in this area. Herein, we review current topics in glycemic control for both the wearable artificial pancreas for type 1 and type 2 diabetic patients and the bedside artificial pancreas for surgical diabetic patients. In type 1 diabetic patients, nocturnal hypoglycemia associated with insulin therapy remains a serious problem that could be addressed by the recent development of a wearable artificial pancreas. This smart phone-like device, comprising a real-time, continuous glucose monitoring system and insulin pump system, could potentially significantly reduce nocturnal hypoglycemia compared with conventional glycemic control. Of particular interest in this space are the recent inventions of a low-glucose suspend feature in the portable systems that automatically stops insulin delivery 2 h following a glucose sensor value <70 mg/dL and a bio-hormonal pump system consisting of insulin and glucagon pumps. Perioperative tight glycemic control using a bedside artificial pancreas with the closed-loop system has also proved safe and effective for not only avoiding hypoglycemia, but also for reducing blood glucose level variability resulting in good surgical outcomes. We hope that a more sophisticated artificial pancreas with closed-loop system will now be taken up for routine use worldwide, providing enormous relief for patients suffering from uncontrolled hyperglycemia, hypoglycemia, and/or variability in blood glucose concentrations.

Original languageEnglish
Pages (from-to)209-218
Number of pages10
JournalJournal of Artificial Organs
Volume19
Issue number3
DOIs
Publication statusPublished - 01-09-2016

All Science Journal Classification (ASJC) codes

  • Medicine (miscellaneous)
  • Biomaterials
  • Biomedical Engineering
  • Cardiology and Cardiovascular Medicine

Fingerprint

Dive into the research topics of 'Current topics in glycemic control by wearable artificial pancreas or bedside artificial pancreas with closed-loop system'. Together they form a unique fingerprint.

Cite this