Development and evaluation of QA software for the monitor chamber of an accelerator

Takeshi Tsuzuki, Hidenori Kameshima, Masanao Kobayashi, Syouichi Suzuki

Research output: Contribution to journalArticle

Abstract

The monitor chamber of a radiotherapy system needs to be calibrated once a week. Because the calibration procedure requires a large variety of complicated calculations, we have developed software that facilitates calculation and enables comparison and storage of data. According to the standard measurement of absorbed dose, we used Visual Basic 6.0 (Microsoft Corp.) to establish the calibration method. This new technique has simplified the conventional intricate calculation required for calibration of the monitor chamber and enabled automatic processing of calculated results. We have confirmed the usefulness of this software in calibrating the monitor chamber. In the routine inspection, we can compare the current data with former results. Because of this advantage, it is possible to eliminate serious accidents such as overdosing and underdosing.

Original languageEnglish
Pages (from-to)1402-1410
Number of pages9
JournalNippon Hoshasen Gijutsu Gakkai zasshi
Volume58
Issue number10
DOIs
Publication statusPublished - 01-01-2002

Fingerprint

Calibration
Software
Information Storage and Retrieval
Accidents
Radiotherapy

All Science Journal Classification (ASJC) codes

  • Medicine(all)

Cite this

Tsuzuki, Takeshi ; Kameshima, Hidenori ; Kobayashi, Masanao ; Suzuki, Syouichi. / Development and evaluation of QA software for the monitor chamber of an accelerator. In: Nippon Hoshasen Gijutsu Gakkai zasshi. 2002 ; Vol. 58, No. 10. pp. 1402-1410.
@article{24d77edd0fd141728a2ddad6933d8f4c,
title = "Development and evaluation of QA software for the monitor chamber of an accelerator",
abstract = "The monitor chamber of a radiotherapy system needs to be calibrated once a week. Because the calibration procedure requires a large variety of complicated calculations, we have developed software that facilitates calculation and enables comparison and storage of data. According to the standard measurement of absorbed dose, we used Visual Basic 6.0 (Microsoft Corp.) to establish the calibration method. This new technique has simplified the conventional intricate calculation required for calibration of the monitor chamber and enabled automatic processing of calculated results. We have confirmed the usefulness of this software in calibrating the monitor chamber. In the routine inspection, we can compare the current data with former results. Because of this advantage, it is possible to eliminate serious accidents such as overdosing and underdosing.",
author = "Takeshi Tsuzuki and Hidenori Kameshima and Masanao Kobayashi and Syouichi Suzuki",
year = "2002",
month = "1",
day = "1",
doi = "10.6009/jjrt.KJ00003111391",
language = "English",
volume = "58",
pages = "1402--1410",
journal = "Nippon Hoshasen Gijutsu Gakkai zasshi",
issn = "0369-4305",
publisher = "Nihon Hoshasen Gijutsu Gakkai/Japanese Society of Radiological Technology",
number = "10",

}

Development and evaluation of QA software for the monitor chamber of an accelerator. / Tsuzuki, Takeshi; Kameshima, Hidenori; Kobayashi, Masanao; Suzuki, Syouichi.

In: Nippon Hoshasen Gijutsu Gakkai zasshi, Vol. 58, No. 10, 01.01.2002, p. 1402-1410.

Research output: Contribution to journalArticle

TY - JOUR

T1 - Development and evaluation of QA software for the monitor chamber of an accelerator

AU - Tsuzuki, Takeshi

AU - Kameshima, Hidenori

AU - Kobayashi, Masanao

AU - Suzuki, Syouichi

PY - 2002/1/1

Y1 - 2002/1/1

N2 - The monitor chamber of a radiotherapy system needs to be calibrated once a week. Because the calibration procedure requires a large variety of complicated calculations, we have developed software that facilitates calculation and enables comparison and storage of data. According to the standard measurement of absorbed dose, we used Visual Basic 6.0 (Microsoft Corp.) to establish the calibration method. This new technique has simplified the conventional intricate calculation required for calibration of the monitor chamber and enabled automatic processing of calculated results. We have confirmed the usefulness of this software in calibrating the monitor chamber. In the routine inspection, we can compare the current data with former results. Because of this advantage, it is possible to eliminate serious accidents such as overdosing and underdosing.

AB - The monitor chamber of a radiotherapy system needs to be calibrated once a week. Because the calibration procedure requires a large variety of complicated calculations, we have developed software that facilitates calculation and enables comparison and storage of data. According to the standard measurement of absorbed dose, we used Visual Basic 6.0 (Microsoft Corp.) to establish the calibration method. This new technique has simplified the conventional intricate calculation required for calibration of the monitor chamber and enabled automatic processing of calculated results. We have confirmed the usefulness of this software in calibrating the monitor chamber. In the routine inspection, we can compare the current data with former results. Because of this advantage, it is possible to eliminate serious accidents such as overdosing and underdosing.

UR - http://www.scopus.com/inward/record.url?scp=0036824361&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=0036824361&partnerID=8YFLogxK

U2 - 10.6009/jjrt.KJ00003111391

DO - 10.6009/jjrt.KJ00003111391

M3 - Article

VL - 58

SP - 1402

EP - 1410

JO - Nippon Hoshasen Gijutsu Gakkai zasshi

JF - Nippon Hoshasen Gijutsu Gakkai zasshi

SN - 0369-4305

IS - 10

ER -