Development of quality control system for flat-panel detectors

Atsushi Teramoto, Takahiko Kajihara, Shoichi Suzuki, Kazuo Kinoshita, Masatoshi Tsuzaka, Hiroshi Fujita

Research output: Contribution to journalArticle

2 Citations (Scopus)

Abstract

The characteristics of flat-panel detectors (FPD) are degraded by exposure to radiation. Degradation in a FPD progresses locally and has a nonlinear relationship to the radiation dose. In order to manage FPD systems properly, one must perform quality control (QC) such as evaluation of image degradation. However, no evaluation method for degradation has been established. In this paper, we first review the structure and degradation mechanism of FPDs, and then we propose a daily QC system for FPDs. To evaluate the degradation of FPDs, we investigated the number of defective pixels and lines, as well as the offset level of the pixel output. Furthermore, we developed daily QC software for FPD that can evaluate the image quality and is operationally simple. In the experiments, an indirect-conversion type FPD was evaluated by our proposed system. The offset level of FPD increased exponentially with X-ray exposure; no trends were seen for the number of defective pixels and defective lines. The required time for the evaluation of an FPD was about 1 min, and no special skills were needed for the analysis. These results indicate that our system may be useful for daily QC of FPDs.

Original languageEnglish
Pages (from-to)164-172
Number of pages9
JournalRadiological Physics and Technology
Volume4
Issue number2
DOIs
Publication statusPublished - 01-07-2011

Fingerprint

quality control
Quality Control
detectors
degradation
pixels
evaluation
Software
X-Rays
Radiation
radiation
computer programs
trends
dosage
output
x rays

All Science Journal Classification (ASJC) codes

  • Radiation
  • Physical Therapy, Sports Therapy and Rehabilitation
  • Radiology Nuclear Medicine and imaging

Cite this

Teramoto, Atsushi ; Kajihara, Takahiko ; Suzuki, Shoichi ; Kinoshita, Kazuo ; Tsuzaka, Masatoshi ; Fujita, Hiroshi. / Development of quality control system for flat-panel detectors. In: Radiological Physics and Technology. 2011 ; Vol. 4, No. 2. pp. 164-172.
@article{11e6c7666d414383a13c12e182be248e,
title = "Development of quality control system for flat-panel detectors",
abstract = "The characteristics of flat-panel detectors (FPD) are degraded by exposure to radiation. Degradation in a FPD progresses locally and has a nonlinear relationship to the radiation dose. In order to manage FPD systems properly, one must perform quality control (QC) such as evaluation of image degradation. However, no evaluation method for degradation has been established. In this paper, we first review the structure and degradation mechanism of FPDs, and then we propose a daily QC system for FPDs. To evaluate the degradation of FPDs, we investigated the number of defective pixels and lines, as well as the offset level of the pixel output. Furthermore, we developed daily QC software for FPD that can evaluate the image quality and is operationally simple. In the experiments, an indirect-conversion type FPD was evaluated by our proposed system. The offset level of FPD increased exponentially with X-ray exposure; no trends were seen for the number of defective pixels and defective lines. The required time for the evaluation of an FPD was about 1 min, and no special skills were needed for the analysis. These results indicate that our system may be useful for daily QC of FPDs.",
author = "Atsushi Teramoto and Takahiko Kajihara and Shoichi Suzuki and Kazuo Kinoshita and Masatoshi Tsuzaka and Hiroshi Fujita",
year = "2011",
month = "7",
day = "1",
doi = "10.1007/s12194-011-0117-2",
language = "English",
volume = "4",
pages = "164--172",
journal = "Radiological Physics and Technology",
issn = "1865-0333",
publisher = "Springer Japan",
number = "2",

}

Teramoto, A, Kajihara, T, Suzuki, S, Kinoshita, K, Tsuzaka, M & Fujita, H 2011, 'Development of quality control system for flat-panel detectors', Radiological Physics and Technology, vol. 4, no. 2, pp. 164-172. https://doi.org/10.1007/s12194-011-0117-2

Development of quality control system for flat-panel detectors. / Teramoto, Atsushi; Kajihara, Takahiko; Suzuki, Shoichi; Kinoshita, Kazuo; Tsuzaka, Masatoshi; Fujita, Hiroshi.

In: Radiological Physics and Technology, Vol. 4, No. 2, 01.07.2011, p. 164-172.

Research output: Contribution to journalArticle

TY - JOUR

T1 - Development of quality control system for flat-panel detectors

AU - Teramoto, Atsushi

AU - Kajihara, Takahiko

AU - Suzuki, Shoichi

AU - Kinoshita, Kazuo

AU - Tsuzaka, Masatoshi

AU - Fujita, Hiroshi

PY - 2011/7/1

Y1 - 2011/7/1

N2 - The characteristics of flat-panel detectors (FPD) are degraded by exposure to radiation. Degradation in a FPD progresses locally and has a nonlinear relationship to the radiation dose. In order to manage FPD systems properly, one must perform quality control (QC) such as evaluation of image degradation. However, no evaluation method for degradation has been established. In this paper, we first review the structure and degradation mechanism of FPDs, and then we propose a daily QC system for FPDs. To evaluate the degradation of FPDs, we investigated the number of defective pixels and lines, as well as the offset level of the pixel output. Furthermore, we developed daily QC software for FPD that can evaluate the image quality and is operationally simple. In the experiments, an indirect-conversion type FPD was evaluated by our proposed system. The offset level of FPD increased exponentially with X-ray exposure; no trends were seen for the number of defective pixels and defective lines. The required time for the evaluation of an FPD was about 1 min, and no special skills were needed for the analysis. These results indicate that our system may be useful for daily QC of FPDs.

AB - The characteristics of flat-panel detectors (FPD) are degraded by exposure to radiation. Degradation in a FPD progresses locally and has a nonlinear relationship to the radiation dose. In order to manage FPD systems properly, one must perform quality control (QC) such as evaluation of image degradation. However, no evaluation method for degradation has been established. In this paper, we first review the structure and degradation mechanism of FPDs, and then we propose a daily QC system for FPDs. To evaluate the degradation of FPDs, we investigated the number of defective pixels and lines, as well as the offset level of the pixel output. Furthermore, we developed daily QC software for FPD that can evaluate the image quality and is operationally simple. In the experiments, an indirect-conversion type FPD was evaluated by our proposed system. The offset level of FPD increased exponentially with X-ray exposure; no trends were seen for the number of defective pixels and defective lines. The required time for the evaluation of an FPD was about 1 min, and no special skills were needed for the analysis. These results indicate that our system may be useful for daily QC of FPDs.

UR - http://www.scopus.com/inward/record.url?scp=79960465790&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=79960465790&partnerID=8YFLogxK

U2 - 10.1007/s12194-011-0117-2

DO - 10.1007/s12194-011-0117-2

M3 - Article

VL - 4

SP - 164

EP - 172

JO - Radiological Physics and Technology

JF - Radiological Physics and Technology

SN - 1865-0333

IS - 2

ER -