TY - JOUR
T1 - Diagnostic performance of the simultaneous acquisition rest 99 mTc-tetrofosmin/stress201Tl dual-isotope protocol with a semiconductor camera
T2 - Comparison with the rest-stress 99 mTc-tetrofosmin protocol
AU - Kawamura, Itta
AU - Kajiura, Ryo
AU - Motoji, Yusuke
AU - Okamoto, Syuichi
AU - Tanigaki, Toru
AU - Omori, Hiroyuki
AU - Hirata, Tetsuo
AU - Kikuchi, Jun
AU - Ota, Hideaki
AU - Sobue, Yoshihiro
AU - Miyake, Taiji
AU - Tsunekawa, Tomohiro
AU - Kato, Takayoshi
AU - Kawase, Yoshiaki
AU - Okubo, Munenori
AU - Kamiya, Hiroki
AU - Tsuchiya, Kunihiko
AU - Tomita, Shinji
AU - Hirakawa, Akihiro
AU - Kondo, Takeshi
AU - Suzuki, Takahiko
AU - Matsuo, Hitoshi
N1 - Publisher Copyright:
© 2018, Japanese Circulation Society. All rights reserved.
PY - 2018
Y1 - 2018
N2 - Background: This study compared the diagnostic value of myocardial perfusion imaging (MPI) between the rest-stress99 m Tc-tetrofosmin protocol (Tc/Tc protocol) and simultaneous acquisition rest99 mTc-tetrofosmin/stress201Tl dual-isotope protocol (SDI protocol) with a semiconductor camera. Methods and Results: We retrospectively studied 147 patients who underwent stress MPI using a cadmium-zinc-telluride camera and invasive coronary angiography within a 3-month interval. The Tc/Tc and SDI protocols were used in 59 and 88 patients, respectively. The sensitivity, specificity, and accuracy of the summed difference score in per-patient analysis were 56%, 85%, and 69%, respectively, for the Tc/Tc protocol and 89%, 82%, and 85%, respectively, for the SDI protocol. The area under the receiver operating characteristic curve was significantly better for the SDI than Tc/Tc protocol for the left anterior descending artery (0.836 vs. 0.674; P=0.0380), the left circumflex artery (0.754 vs. 0.599; P=0.0441), and in per-patient analysis (0.875 vs. 0.707; P=0.0135). There was no significant difference in the diagnostic accuracy of the summed stress score for any vessel or in per-patient analysis between the 2 protocols. Conclusions: The SDI protocol had a higher diagnostic accuracy for the detection of coronary ischemia than the Tc/Tc protocol.
AB - Background: This study compared the diagnostic value of myocardial perfusion imaging (MPI) between the rest-stress99 m Tc-tetrofosmin protocol (Tc/Tc protocol) and simultaneous acquisition rest99 mTc-tetrofosmin/stress201Tl dual-isotope protocol (SDI protocol) with a semiconductor camera. Methods and Results: We retrospectively studied 147 patients who underwent stress MPI using a cadmium-zinc-telluride camera and invasive coronary angiography within a 3-month interval. The Tc/Tc and SDI protocols were used in 59 and 88 patients, respectively. The sensitivity, specificity, and accuracy of the summed difference score in per-patient analysis were 56%, 85%, and 69%, respectively, for the Tc/Tc protocol and 89%, 82%, and 85%, respectively, for the SDI protocol. The area under the receiver operating characteristic curve was significantly better for the SDI than Tc/Tc protocol for the left anterior descending artery (0.836 vs. 0.674; P=0.0380), the left circumflex artery (0.754 vs. 0.599; P=0.0441), and in per-patient analysis (0.875 vs. 0.707; P=0.0135). There was no significant difference in the diagnostic accuracy of the summed stress score for any vessel or in per-patient analysis between the 2 protocols. Conclusions: The SDI protocol had a higher diagnostic accuracy for the detection of coronary ischemia than the Tc/Tc protocol.
UR - http://www.scopus.com/inward/record.url?scp=85055523215&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=85055523215&partnerID=8YFLogxK
U2 - 10.1253/circj.CJ-18-0363
DO - 10.1253/circj.CJ-18-0363
M3 - Article
C2 - 30175800
AN - SCOPUS:85055523215
SN - 1346-9843
VL - 82
SP - 2837
EP - 2844
JO - Circulation Journal
JF - Circulation Journal
IS - 11
ER -