T1 - Dose estimation with CTDI100, air in computed tomography
AU - Kobayashi, Masanao
AU - Kataoka, Yumi
AU - Ida, Yoshihiro
AU - Asada, Yasuki
AU - Suzuki, Syoichi
AU - Katada, Kazuhiro
PY - 2004/11
Y1 - 2004/11
N2 - Although the principal dosimetric quantity in computed tomography (CT) can be assessed using a pencil ionization chamber with an active length of 100 mm, standard CT dosimetry phantoms of polymethylmethacrylate (PMMA) , and plates of aluminum, most facilities do not possess the requisites. We present a practical method of estimating CTDI(100, c), CTDI(100, p) and the half-value layer (HVL) from CTDI(100, air), which is measured parallel with the axis of rotation of the scanner to free-in-air. The three data chosen for this method of estimation were as follows: 1) the relation of HVL to CTDI(100, air) per radiographic exposure (mAs); 2) the relation of HVL to CTDI(100, c) per CTDI(100, air); 3) the relation of HVL to CTDI(100, p) per CTDI(100, air). The data were based on the measured values of six CT scanners, so as to avoid dependence on the technical characteristics of a specific manufacturer. The estimated value has a possible maximum uncertainty of 20%, although this method of estimation is practical for dose assessment.
AB - Although the principal dosimetric quantity in computed tomography (CT) can be assessed using a pencil ionization chamber with an active length of 100 mm, standard CT dosimetry phantoms of polymethylmethacrylate (PMMA) , and plates of aluminum, most facilities do not possess the requisites. We present a practical method of estimating CTDI(100, c), CTDI(100, p) and the half-value layer (HVL) from CTDI(100, air), which is measured parallel with the axis of rotation of the scanner to free-in-air. The three data chosen for this method of estimation were as follows: 1) the relation of HVL to CTDI(100, air) per radiographic exposure (mAs); 2) the relation of HVL to CTDI(100, c) per CTDI(100, air); 3) the relation of HVL to CTDI(100, p) per CTDI(100, air). The data were based on the measured values of six CT scanners, so as to avoid dependence on the technical characteristics of a specific manufacturer. The estimated value has a possible maximum uncertainty of 20%, although this method of estimation is practical for dose assessment.
UR - http://www.scopus.com/inward/record.url?scp=16644362586&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=16644362586&partnerID=8YFLogxK
U2 - 10.6009/jjrt.KJ00003326576
DO - 10.6009/jjrt.KJ00003326576
M3 - Article
C2 - 15568004
AN - SCOPUS:16644362586
SN - 0369-4305
VL - 60
SP - 1526
EP - 1532
JO - Nippon Hoshasen Gijutsu Gakkai zasshi
JF - Nippon Hoshasen Gijutsu Gakkai zasshi
IS - 11
ER -