TY - JOUR
T1 - Effect of reconstruction algorithm on image quality and identification of ground-glass opacities and partly solid nodules on low-dose thin-section CT
T2 - Experimental study using chest phantom
AU - Koyama, Hisanobu
AU - Ohno, Yoshiharu
AU - Kono, Atsushi A.
AU - Kusaka, Akiko
AU - Konishi, Minoru
AU - Yoshii, Masaru
AU - Sugimura, Kazuro
N1 - Funding Information:
This work was supported by Philips Medical Systems.
PY - 2010/6
Y1 - 2010/6
N2 - Purpose: The purpose of this study was to assess the influence of reconstruction algorithm on identification and image quality of ground-glass opacities (GGOs) and partly solid nodules on low-dose thin-section CT. Materials and methods: A chest CT phantom including simulated GGOs and partly solid nodules was scanned with five different tube currents and reconstructed by using standard (A) and newly developed (B) high-resolution reconstruction algorithms, followed by visually assessment of identification and image quality of GGOs and partly solid nodules by two chest radiologists. Inter-observer agreement, ROC analysis and ANOVA were performed to compare identification and image quality of each data set with those of the standard reference. The standard reference used 120 mA s in conjunction with reconstruction algorithm A. Results: Kappa values (κ) of overall identification and image qualities were substantial or almost perfect (0.60 < κ). Assessment of identification showed that area under the curve of 25 mA reconstructed with reconstruction algorithm A was significantly lower than that of standard reference (p < 0.05), while assessment of image quality indicated that 50 mA s reconstructed with reconstruction algorithm A and 25 mA s reconstructed with both reconstruction algorithms were significantly lower than standard reference (p < 0.05). Conclusion: Reconstruction algorithm may be an important factor for identification and image quality of ground-glass opacities and partly solid nodules on low-dose CT examination.
AB - Purpose: The purpose of this study was to assess the influence of reconstruction algorithm on identification and image quality of ground-glass opacities (GGOs) and partly solid nodules on low-dose thin-section CT. Materials and methods: A chest CT phantom including simulated GGOs and partly solid nodules was scanned with five different tube currents and reconstructed by using standard (A) and newly developed (B) high-resolution reconstruction algorithms, followed by visually assessment of identification and image quality of GGOs and partly solid nodules by two chest radiologists. Inter-observer agreement, ROC analysis and ANOVA were performed to compare identification and image quality of each data set with those of the standard reference. The standard reference used 120 mA s in conjunction with reconstruction algorithm A. Results: Kappa values (κ) of overall identification and image qualities were substantial or almost perfect (0.60 < κ). Assessment of identification showed that area under the curve of 25 mA reconstructed with reconstruction algorithm A was significantly lower than that of standard reference (p < 0.05), while assessment of image quality indicated that 50 mA s reconstructed with reconstruction algorithm A and 25 mA s reconstructed with both reconstruction algorithms were significantly lower than standard reference (p < 0.05). Conclusion: Reconstruction algorithm may be an important factor for identification and image quality of ground-glass opacities and partly solid nodules on low-dose CT examination.
UR - http://www.scopus.com/inward/record.url?scp=77952877597&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=77952877597&partnerID=8YFLogxK
U2 - 10.1016/j.ejrad.2009.03.013
DO - 10.1016/j.ejrad.2009.03.013
M3 - Article
C2 - 19362441
AN - SCOPUS:77952877597
SN - 0720-048X
VL - 74
SP - 500
EP - 507
JO - European journal of radiology
JF - European journal of radiology
IS - 3
ER -