TY - JOUR
T1 - Electrode-specific dosimetric robustness of group-level optimized transcranial alternating current and temporal interference stimulation montages under placement variability
AU - Yamada, Eikei
AU - Inoue, Taiga
AU - Otsuru, Naofumi
AU - Suzuki, Makoto
AU - Uehara, Shintaro
AU - Otaka, Yohei
AU - Hirata, Akimasa
N1 - Publisher Copyright:
© 2026 The Author(s). Published on behalf of Institute of Physics and Engineering in Medicine by IOP Publishing Ltd. Original content from this work may be used under the terms of the Creative Commons Attribution 4.0 license. Any further distribution of this work must maintain attribution to the author(s) and the title of the work, journal citation and DOI.
PY - 2026/10/14
Y1 - 2026/10/14
N2 - Objective. The objective of this study was to characterize, for selected group-level optimized montages, electrode-specific dosimetric sensitivity to placement variability in transcranial alternating current stimulation (tACS) and transcranial temporal interference stimulation (tTIS). Approach. Electric fields (EFs) were computed using the scalar-potential finite-difference method in 60 paired model instances generated from magnetic resonance imaging data of 30 male participants (30 original models and their left–right mirrored counterparts). Three anatomically defined targets spanning cortical and subcortical structures were examined: the primary somatosensory hand area (S1 Hand), the insula, and the hippocampus. Every electrode constituting each selected montage was independently displaced from −10 mm to +10 mm in 5 mm increments on a 5 × 5 tangential grid. Three descriptive outcomes were evaluated: intensity sensitivity, defined as the absolute percentage change in the region-of-interest mean; hotspot displacement; and position-dependent intensity variability, defined as the standard deviation (SD) of the percentage change across the full ±10 mm grid. Main results. Across all 16 displaced electrodes, intensity sensitivity ranged from 0.41%–14.88%, and hotspot displacement ranged from 0.63–6.86 mm. Marked within-pair asymmetries were observed in several montages, and position-dependent intensity variability differed across electrodes and model instances. These patterns were descriptively associated with montage geometry and current allocation. Significance. The independent all-electrode perturbation framework introduced here enables electrode-specific robustness assessment of group-level optimized tACS and tTIS montages. The results identify montage-specific electrodes for which placement control is particularly important within the studied configurations, informing the practical implementation of these montages.
AB - Objective. The objective of this study was to characterize, for selected group-level optimized montages, electrode-specific dosimetric sensitivity to placement variability in transcranial alternating current stimulation (tACS) and transcranial temporal interference stimulation (tTIS). Approach. Electric fields (EFs) were computed using the scalar-potential finite-difference method in 60 paired model instances generated from magnetic resonance imaging data of 30 male participants (30 original models and their left–right mirrored counterparts). Three anatomically defined targets spanning cortical and subcortical structures were examined: the primary somatosensory hand area (S1 Hand), the insula, and the hippocampus. Every electrode constituting each selected montage was independently displaced from −10 mm to +10 mm in 5 mm increments on a 5 × 5 tangential grid. Three descriptive outcomes were evaluated: intensity sensitivity, defined as the absolute percentage change in the region-of-interest mean; hotspot displacement; and position-dependent intensity variability, defined as the standard deviation (SD) of the percentage change across the full ±10 mm grid. Main results. Across all 16 displaced electrodes, intensity sensitivity ranged from 0.41%–14.88%, and hotspot displacement ranged from 0.63–6.86 mm. Marked within-pair asymmetries were observed in several montages, and position-dependent intensity variability differed across electrodes and model instances. These patterns were descriptively associated with montage geometry and current allocation. Significance. The independent all-electrode perturbation framework introduced here enables electrode-specific robustness assessment of group-level optimized tACS and tTIS montages. The results identify montage-specific electrodes for which placement control is particularly important within the studied configurations, informing the practical implementation of these montages.
KW - dosimetric robustness
KW - electric field simulation
KW - electrode placement variability
KW - group-level optimized montage
KW - temporal interference stimulation
KW - transcranial alternating current stimulation
UR - https://www.scopus.com/pages/publications/105053447129
UR - https://www.scopus.com/pages/publications/105053447129#tab=citedBy
U2 - 10.1088/1361-6560/aeae9c
DO - 10.1088/1361-6560/aeae9c
M3 - Article
C2 - 42815533
AN - SCOPUS:105053447129
SN - 0031-9155
VL - 71
JO - Physics in Medicine and Biology
JF - Physics in Medicine and Biology
IS - 19
M1 - 195041
ER -