T1 - Evaluation of exposure dose in fetal computed tomography using organ-effective modulation
AU - Kobayashi, Masanao
AU - Haba, Tomonobu
AU - Suzuki, Sayaka
AU - Nishihara, Yusei
AU - Asada, Yasuki
AU - Minami, Kazuyuki
N1 - Funding Information:
This research was conducted with financial assistance from JSPS KAKENHI Grant Number JP 19K17152. Acknowledgements
Publisher Copyright:
© 2020, The Author(s).
PY - 2020/12
Y1 - 2020/12
N2 - Organ-effective modulation (OEM) is a computed tomography scanning technique that reduces the exposure dose to organs at risk. Ultrasonography is commonly used for prenatal imaging, but its reliability is reported to be limited. Radiography and computed tomography (CT) are reliable but pose risk of radiation exposure to the pregnant woman and her fetus. Although there are many reports on the exposure dose associated with fetal CT scans, no reports exist on OEM use in fetal CT scans. We measured the basic characteristics of organ-effective modulation (X-ray output modulation angle, maximum X-ray output modulation rate, total X-ray output modulation rate, and noise modulation) and used them in a Monte Carlo simulation to evaluate the effect of this technique on fetal CT scans in terms of image quality and exposure dose to the pregnant woman and fetus. Using ImPACT MC software, Monte Carlo simulations of OEMON and OEMOFF were run on 8 cases involving fetal CT scans. We confirmed that the organ-effective modulation X-ray output modulation angle was 160°; the X-ray output modulation rate increased with increasing tube current; and no modulation occurred at tube currents of 80 mA or below. Our findings suggest that OEM has only a minimal effect in reducing organ exposure in pregnant women; therefore, it should be used on the anterior side (OEMON,front) to reduce the exposure dose to the fetus.
AB - Organ-effective modulation (OEM) is a computed tomography scanning technique that reduces the exposure dose to organs at risk. Ultrasonography is commonly used for prenatal imaging, but its reliability is reported to be limited. Radiography and computed tomography (CT) are reliable but pose risk of radiation exposure to the pregnant woman and her fetus. Although there are many reports on the exposure dose associated with fetal CT scans, no reports exist on OEM use in fetal CT scans. We measured the basic characteristics of organ-effective modulation (X-ray output modulation angle, maximum X-ray output modulation rate, total X-ray output modulation rate, and noise modulation) and used them in a Monte Carlo simulation to evaluate the effect of this technique on fetal CT scans in terms of image quality and exposure dose to the pregnant woman and fetus. Using ImPACT MC software, Monte Carlo simulations of OEMON and OEMOFF were run on 8 cases involving fetal CT scans. We confirmed that the organ-effective modulation X-ray output modulation angle was 160°; the X-ray output modulation rate increased with increasing tube current; and no modulation occurred at tube currents of 80 mA or below. Our findings suggest that OEM has only a minimal effect in reducing organ exposure in pregnant women; therefore, it should be used on the anterior side (OEMON,front) to reduce the exposure dose to the fetus.
UR - http://www.scopus.com/inward/record.url?scp=85091008001&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=85091008001&partnerID=8YFLogxK
U2 - 10.1007/s13246-020-00921-z
DO - 10.1007/s13246-020-00921-z
M3 - Article
C2 - 32926394
AN - SCOPUS:85091008001
SN - 2662-4729
VL - 43
SP - 1195
EP - 1206
JO - Physical and Engineering Sciences in Medicine
JF - Physical and Engineering Sciences in Medicine
IS - 4
ER -