T1 - Evaluation of radiation exposure dose at double-balloon endoscopy for the patients with small bowel disease
AU - Nagura, Asuka
AU - Nakamura, Masanao
AU - Watanabe, Osamu
AU - Yamamura, Takeshi
AU - Funasaka, Kohei
AU - Ohno, Eizaburo
AU - Miyahara, Ryoji
AU - Kawashima, Hiroki
AU - Koyama, Shuji
AU - Hinami, Tomoki
AU - Goto, Hidemi
AU - Hirooka, Yoshiki
PY - 2016
Y1 - 2016
N2 - Double-balloon endoscopy (DBE) is useful for the diagnosis and treatment of small bowel diseases. Although fluoroscopy is used to confirm the position of endoscope at DBE, the endoscopist does not have the knowledge with regard to the radiation exposure dose. In this study, we evaluated the absorbed dose during DBE in patients with suspected or established small bowel diseases. This was a retrospective study in which the estimated fluoroscopic radiation absorbed doses loaded on the small bowel and skin were determined according to the data of the referential X-ray experiment with a human body phantom. The subjects were 415 DBEs preformed in total. The mean small bowel absorbed doses on antegrade and retrograde DBEs were 42.2 and 53.8 mGy, respectively, showing that the organ dose applied in retrograde DBE was significantly higher (P < 0.0001). The mean skin absorbed doses of them were 79.2 and 101.0 mGy, respectively, showing that the dose was also significantly higher on retrograde DBE (P < 0.0001). Of 27 cases who were applied endoscopic balloon dilation, the mean fluoroscopy time was 16.0 minutes, and mean small bowel and skin absorbed doses were 121.9 and 228.9 mGy, respectively. In conclusion, endoscopist should be careful for reducing the organ exposure dose at DBE, particularly for the lower abdominal region.
AB - Double-balloon endoscopy (DBE) is useful for the diagnosis and treatment of small bowel diseases. Although fluoroscopy is used to confirm the position of endoscope at DBE, the endoscopist does not have the knowledge with regard to the radiation exposure dose. In this study, we evaluated the absorbed dose during DBE in patients with suspected or established small bowel diseases. This was a retrospective study in which the estimated fluoroscopic radiation absorbed doses loaded on the small bowel and skin were determined according to the data of the referential X-ray experiment with a human body phantom. The subjects were 415 DBEs preformed in total. The mean small bowel absorbed doses on antegrade and retrograde DBEs were 42.2 and 53.8 mGy, respectively, showing that the organ dose applied in retrograde DBE was significantly higher (P < 0.0001). The mean skin absorbed doses of them were 79.2 and 101.0 mGy, respectively, showing that the dose was also significantly higher on retrograde DBE (P < 0.0001). Of 27 cases who were applied endoscopic balloon dilation, the mean fluoroscopy time was 16.0 minutes, and mean small bowel and skin absorbed doses were 121.9 and 228.9 mGy, respectively. In conclusion, endoscopist should be careful for reducing the organ exposure dose at DBE, particularly for the lower abdominal region.
UR - http://www.scopus.com/inward/record.url?scp=84994103444&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=84994103444&partnerID=8YFLogxK
M3 - Article
C2 - 27578908
AN - SCOPUS:84994103444
SN - 0027-7622
VL - 78
SP - 245
EP - 253
JO - Nagoya journal of medical science
JF - Nagoya journal of medical science
IS - 3
ER -