Evaluation of radiophotoluminescent glass dosimeter response for therapeutic spot scanning proton beam: suggestion of linear energy transfer-based correction

Junya Nagata, Keisuke Yasui, Chihiro Omachi, Toshito Toshiyuki, Hidetoshi Shimizu, Takahiro Aoyama, Naoki Hayashi

Research output: Contribution to journalArticlepeer-review

4 Citations (Scopus)

Abstract

A radiophotoluminescent glass dosimeter (RGD) is used for a postal audit of a photon beam because of its various excellent characteristics. However, it has not been used for scanning proton beams because its response characteristics have not been verified. In this study, the response of RGD to scanning protons was investigated to develop a dosimetry protocol using the linear energy transfer (LET)-based correction factor. The responses of RGD to four maximum-range-energy-pattern proton beams were verified by comparing it with ionization chamber (IC) dosimetry. The LET at each measurement depth was calculated via Monte Carlo (MC) simulation. The LET correction factor ((Formula presented.)) was the ratio between the uncorrected RGD dose ((Formula presented.)) and the IC dose at each measurement depth. (Formula presented.) can be represented as a function of LET using the following equation: (Formula presented.). (Formula presented.) showed a linear under-response with increasing LET, and the maximum dose difference between the IC dose and (Formula presented.) was 15.2% at an LET of 6.07 keV/μm. The LET-based correction dose ((Formula presented.)) conformed within 3.6% of the IC dose. The mean dose difference (±SD) of (Formula presented.) and (Formula presented.) was –2.5 ± 6.9% and 0.0 ± 1.6%, respectively. To achieve accurate dose verification for scanning proton beams using RGD, we derived a linear regression equation based on LET. The results show that with appropriate LET correction, RGD can be used for dose verification of scanning proton beams.

Original languageEnglish
Pages (from-to)265-272
Number of pages8
JournalJournal of applied clinical medical physics
Volume22
Issue number8
DOIs
Publication statusPublished - 08-2021

All Science Journal Classification (ASJC) codes

  • Radiation
  • Instrumentation
  • Radiology Nuclear Medicine and imaging

Fingerprint

Dive into the research topics of 'Evaluation of radiophotoluminescent glass dosimeter response for therapeutic spot scanning proton beam: suggestion of linear energy transfer-based correction'. Together they form a unique fingerprint.

Cite this