Abstract
We assessed the accuracy of mono-energetic electron and beta-emitting isotope dose-point kernels (DPKs) calculated using the particle and heavy ion transport code system (PHITS) for patient-specific dosimetry in targeted radionuclide treatment (TRT) and compared our data with published data. All mono-energetic and beta-emitting isotope DPKs calculated using PHITS, both in water and compact bone, were in good agreement with those in literature using other MC codes. PHITS provided reliable mono-energetic electron and beta-emitting isotope scaled DPKs for patient-specific dosimetry.
| Original language | English |
|---|---|
| Pages (from-to) | 199-203 |
| Number of pages | 5 |
| Journal | Applied Radiation and Isotopes |
| Volume | 128 |
| DOIs | |
| Publication status | Published - 10-2017 |
| Externally published | Yes |
All Science Journal Classification (ASJC) codes
- Radiation
Fingerprint
Dive into the research topics of 'Evaluation of the accuracy of mono-energetic electron and beta-emitting isotope dose-point kernels using particle and heavy ion transport code system: PHITS'. Together they form a unique fingerprint.Cite this