TY - JOUR
T1 - Exploring the causes of peripheral intravenous catheter failure based on shape of catheters removed from various insertion sites
AU - Murayama, Ryoko
AU - Takahashi, Toshiaki
AU - Tanabe, Hidenori
AU - Yabunaka, Koichi
AU - Oe, Makoto
AU - Komiyama, Chieko
AU - Sanada, Hiromi
PY - 2018
Y1 - 2018
N2 - The risk of peripheral intravenous catheter failure varies according to the insertion site. This study examined catheter shape just after removal to evaluate the causes of catheter failure according to site. This study was a secondary analysis of previous study data. Our observational study was conducted during a 6-month period at The University of Tokyo Hospital. Participants were hospitalized adults who received infusion therapy via a short peripheral catheter. We acquired ultrasound images of blood vessels and surrounding tissues at the catheter insertion site before catheter removal and clinical images of the removed catheters. We analyzed 184 catheters from 142 participants. There were no significant differences in the catheter failure rate (29.9%) among insertion sites. Curvature in the middle of the catheter was present in 9.2% of cases; the median bend angle at the catheter base was 9.1° (range: 0.0°-68.3°). The bend angle of catheters inserted in the upper arm was significantly greater than of catheters in the forearm (p = 0.013). Catheter curvature was related to catheter failure (14.8% of failed catheters had curvature; p = 0.035) and occlusion (35.3% of occluded catheters had curvature; p = 0.008) in upper arm and forearm placements. The median distance from the elbow to the insertion site was shorter for failed catheters than for surviving catheters. To prevent catheter failure, especially occlusion resulting from catheter curvature, a catheter should be inserted at an appropriate insertion site far from the antecubital fossa.
AB - The risk of peripheral intravenous catheter failure varies according to the insertion site. This study examined catheter shape just after removal to evaluate the causes of catheter failure according to site. This study was a secondary analysis of previous study data. Our observational study was conducted during a 6-month period at The University of Tokyo Hospital. Participants were hospitalized adults who received infusion therapy via a short peripheral catheter. We acquired ultrasound images of blood vessels and surrounding tissues at the catheter insertion site before catheter removal and clinical images of the removed catheters. We analyzed 184 catheters from 142 participants. There were no significant differences in the catheter failure rate (29.9%) among insertion sites. Curvature in the middle of the catheter was present in 9.2% of cases; the median bend angle at the catheter base was 9.1° (range: 0.0°-68.3°). The bend angle of catheters inserted in the upper arm was significantly greater than of catheters in the forearm (p = 0.013). Catheter curvature was related to catheter failure (14.8% of failed catheters had curvature; p = 0.035) and occlusion (35.3% of occluded catheters had curvature; p = 0.008) in upper arm and forearm placements. The median distance from the elbow to the insertion site was shorter for failed catheters than for surviving catheters. To prevent catheter failure, especially occlusion resulting from catheter curvature, a catheter should be inserted at an appropriate insertion site far from the antecubital fossa.
UR - http://www.scopus.com/inward/record.url?scp=85055071750&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=85055071750&partnerID=8YFLogxK
U2 - 10.5582/ddt.2018.01024
DO - 10.5582/ddt.2018.01024
M3 - Article
C2 - 29998998
AN - SCOPUS:85055071750
SN - 1881-7831
VL - 12
SP - 170
EP - 177
JO - Drug Discoveries and Therapeutics
JF - Drug Discoveries and Therapeutics
IS - 3
ER -