Frequency analysis of shunt sounds in the arteriovenous fistula on hemodialysis patients

Atsu Todo, Tomomi Kadonaka, Masanori Yoshioka, Ayako Ueno, Masami Mitani, Hitoshi Katsurao, Noriyuki Someya, Hirofumi Hasegawa, Yasumasa Hitomi, Takayuki Nishigaki, Yuko Mizuno-Matsumoto

Research output: Chapter in Book/Report/Conference proceedingConference contribution

7 Citations (Scopus)

Abstract

The aim of this research is to evaluate vascular access (VA) using shunt sounds. We measured the blood flow volume in the brachial artery (FV) and the resistance index (RI) by using ultrasonic diagnostic equipment, and the frequency and spectrum characteristic to the shunt sounds by using an electronic stethoscope. The subjects were fifty hemodialysis patients who had been treated with arteriovenous fistura (AVF). An electronic stethoscope was used for all the subjects to record the shunt sounds of arteriovenous anastomosis with an 8 kHz sampling frequency for 8 seconds. The digitized sound was analyzed by the Fourier transform, and every 10 Hz spectra were examined for acoustic amplitude and spectral energy distribution. Based on the ultrasonographic data, subjects FV >= 500 mL/min) and II (FV < 500 mL/min), and Groups A (RI < 0.6) and B (RI >= 0.6). Spectra distribution on frequency bands were compared between two different groups. The spectra in 41-270 Hz were significantly higher in Group I than in Group II. In Group I, the spectra in 111-160Hz were significantly higher than those in other frequency bands. In Group II, the spectra in 121-140 Hz were significantly higher than in the other frequency bands. Comparing Groups A and B, Group A showed a significantly higher spectrum in the 51-270 Hz, and in particular, the spectra of 121-160 Hz showed significantly higher compared with those of the other frequency bands. In group B, spectra of 131-140 Hz showed significantly higher compared with those of the other frequency bands. From these results, shunt sounds acquired in patients with good AVF function (FV >= 500 mL/min or RI < 0.6) were larger in the spectra of a 51-270 Hz frequency bands and were broad in the frequency domain compared with those in patients with poor AVF function (FV < 500 mL/min or RI >= 0.6). It was found that analyzing the amplitude and frequency features of spectra in shunt sounds would be used for identifying FV and RI.

Original languageEnglish
Title of host publication6th International Conference on Soft Computing and Intelligent Systems, and 13th International Symposium on Advanced Intelligence Systems, SCIS/ISIS 2012
Pages1113-1118
Number of pages6
DOIs
Publication statusPublished - 2012
Externally publishedYes
Event2012 Joint 6th International Conference on Soft Computing and Intelligent Systems, SCIS 2012 and 13th International Symposium on Advanced Intelligence Systems, ISIS 2012 - Kobe, Japan
Duration: 20-11-201224-11-2012

Publication series

Name6th International Conference on Soft Computing and Intelligent Systems, and 13th International Symposium on Advanced Intelligence Systems, SCIS/ISIS 2012

Conference

Conference2012 Joint 6th International Conference on Soft Computing and Intelligent Systems, SCIS 2012 and 13th International Symposium on Advanced Intelligence Systems, ISIS 2012
Country/TerritoryJapan
CityKobe
Period20-11-1224-11-12

All Science Journal Classification (ASJC) codes

  • Artificial Intelligence
  • Software

Fingerprint

Dive into the research topics of 'Frequency analysis of shunt sounds in the arteriovenous fistula on hemodialysis patients'. Together they form a unique fingerprint.

Cite this