TY - JOUR
T1 - Graft Size and Double Scroll Formation Rate in Descemet Membrane Endothelial Keratoplasty
AU - Matsumae, Hiroshi
AU - Yamaguchi, Takefumi
AU - Kusano, Yuki
AU - Shimmura, Shigeto
AU - Kobayashi, Akira
AU - Morizane, Yuki
AU - Shimazaki, Jun
N1 - Publisher Copyright:
© 2022 Taylor & Francis Group, LLC.
PY - 2022
Y1 - 2022
N2 - Purpose: This study aimed to evaluate the usefulness of intentional double scroll formation of donor Descemet membrane (DM) inside a glass tube inserter (the Fogla technique) in DM endothelial keratoplasty (DMEK) for controlled insertion and unfolding of grafts. Methods: Eleven consecutive patients who underwent DMEK were included in this study. We sought to specify graft characteristics in which double scroll configuration was successfully formed using the Fogla technique. We compared donor age, graft size, surgical time, unfolding time, and visual outcomes between patients with and without double scroll configuration. The ability to form double scroll formation of DM grafts of various diameters and unfolding time of DM grafts was evaluated using total seven eye-bank eyes in ex vivo experiments. Results: A double scroll configuration inside a glass tube was successfully obtained in six DMEK grafts (54.5%). When comparing clinical features between those with and without double scroll configuration, only graft size was significantly larger in those with double scroll configuration (7.9 ± 0.2 mm) than in those without (7.4 ± 0.4, P = 0.03). There were no significant differences in other features and clinical outcomes, although unfolding-time was shorter in eyes with double scroll configuration (4.6 ± 2.0 min) compared to those without (8.6 ± 8.1, P = 0.21). Ex vivo experiments showed that unfolding time was significantly shorter in double scroll configuration (2.71 ± 0.49 min) than in single scroll (5.02 ± 0.79, P = 0.01). Conclusions: A double scroll configuration within a glass tube can be obtained more frequently in larger DMEK grafts (8.0 mm in diameter), which may result in easier and faster DMEK procedures.
AB - Purpose: This study aimed to evaluate the usefulness of intentional double scroll formation of donor Descemet membrane (DM) inside a glass tube inserter (the Fogla technique) in DM endothelial keratoplasty (DMEK) for controlled insertion and unfolding of grafts. Methods: Eleven consecutive patients who underwent DMEK were included in this study. We sought to specify graft characteristics in which double scroll configuration was successfully formed using the Fogla technique. We compared donor age, graft size, surgical time, unfolding time, and visual outcomes between patients with and without double scroll configuration. The ability to form double scroll formation of DM grafts of various diameters and unfolding time of DM grafts was evaluated using total seven eye-bank eyes in ex vivo experiments. Results: A double scroll configuration inside a glass tube was successfully obtained in six DMEK grafts (54.5%). When comparing clinical features between those with and without double scroll configuration, only graft size was significantly larger in those with double scroll configuration (7.9 ± 0.2 mm) than in those without (7.4 ± 0.4, P = 0.03). There were no significant differences in other features and clinical outcomes, although unfolding-time was shorter in eyes with double scroll configuration (4.6 ± 2.0 min) compared to those without (8.6 ± 8.1, P = 0.21). Ex vivo experiments showed that unfolding time was significantly shorter in double scroll configuration (2.71 ± 0.49 min) than in single scroll (5.02 ± 0.79, P = 0.01). Conclusions: A double scroll configuration within a glass tube can be obtained more frequently in larger DMEK grafts (8.0 mm in diameter), which may result in easier and faster DMEK procedures.
UR - http://www.scopus.com/inward/record.url?scp=85136756540&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=85136756540&partnerID=8YFLogxK
U2 - 10.1080/02713683.2022.2104318
DO - 10.1080/02713683.2022.2104318
M3 - Article
C2 - 35913024
AN - SCOPUS:85136756540
SN - 0271-3683
VL - 47
SP - 1246
EP - 1251
JO - Current Eye Research
JF - Current Eye Research
IS - 9
ER -