TY - JOUR
T1 - Hemodynamic investigation of the effectiveness of a two overlapping flow diverter configuration for cerebral aneurysm treatment
AU - Uchiyama, Yuya
AU - Fujimura, Soichiro
AU - Takao, Hiroyuki
AU - Suzuki, Takashi
AU - Hayakawa, Motoharu
AU - Ishibashi, Toshihiro
AU - Karagiozov, Kostadin
AU - Fukudome, Koji
AU - Murayama, Yuichi
AU - Yamamoto, Makoto
N1 - Publisher Copyright:
© 2021 by the authors. Licensee MDPI, Basel, Switzerland.
PY - 2021/10
Y1 - 2021/10
N2 - Flow diverters (FDs) are widely employed as endovascular treatment devices for large or wide-neck cerebral aneurysms. Occasionally, overlapped FDs are deployed to enhance the flow diversion effect. In this study, we investigated the hemodynamics of overlapping FDs via computational fluid dynamics (CFD) simulations. We reproduced the arterial geometry of a patient who had experienced the deployment of two overlapping FDs. We utilized two stent patterns, namely the patterns for one FD and two overlapping FDs. We calculated the velocity, mass flow rate, wall shear stress, and pressure loss coefficient as well as their change rates for each pattern relative to the no-FD pattern results. The CFD simulation results indicated that the characteristics of the blood flow inside the aneurysm were minimally affected by the deployment of a single FD; in contrast, the overlapping FD pattern results revealed significant changes in the flow. Further, the velocity at an inspection plane within the aneurysm sac decreased by up to 92.2% and 31.0% in the cases of the overlapping and single FD patterns, respectively, relative to the no-FD pattern. The simulations successfully reproduced the hemodynamics, and the qualitative and quantitative investigations are meaningful with regard to the clinical outcomes of overlapped FD deployment.
AB - Flow diverters (FDs) are widely employed as endovascular treatment devices for large or wide-neck cerebral aneurysms. Occasionally, overlapped FDs are deployed to enhance the flow diversion effect. In this study, we investigated the hemodynamics of overlapping FDs via computational fluid dynamics (CFD) simulations. We reproduced the arterial geometry of a patient who had experienced the deployment of two overlapping FDs. We utilized two stent patterns, namely the patterns for one FD and two overlapping FDs. We calculated the velocity, mass flow rate, wall shear stress, and pressure loss coefficient as well as their change rates for each pattern relative to the no-FD pattern results. The CFD simulation results indicated that the characteristics of the blood flow inside the aneurysm were minimally affected by the deployment of a single FD; in contrast, the overlapping FD pattern results revealed significant changes in the flow. Further, the velocity at an inspection plane within the aneurysm sac decreased by up to 92.2% and 31.0% in the cases of the overlapping and single FD patterns, respectively, relative to the no-FD pattern. The simulations successfully reproduced the hemodynamics, and the qualitative and quantitative investigations are meaningful with regard to the clinical outcomes of overlapped FD deployment.
UR - http://www.scopus.com/inward/record.url?scp=85118331976&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=85118331976&partnerID=8YFLogxK
U2 - 10.3390/bioengineering8100143
DO - 10.3390/bioengineering8100143
M3 - Article
AN - SCOPUS:85118331976
SN - 2306-5354
VL - 8
JO - Bioengineering
JF - Bioengineering
IS - 10
M1 - 143