Skip to main navigation Skip to search Skip to main content

High-resolution chest CT using 1024-matrix reconstruction: phantom and clinical evaluation of image quality and post-processing capability

  • Kana Hayashi
  • , Yoshiyuki Ozawa
  • , Hirotsugu Ohkubo
  • , Katsuhiro Okuda
  • , Hiroshi Kunitomo
  • , Seita Watanabe
  • , Katsuya Kato
  • , Akio Hiwatashi

Research output: Contribution to journal › Article › peer-review

Abstract

Purpose: To evaluate the image quality and clinical utility of high-resolution computed tomography (CT) images reconstructed using post-processing with a 1024 × 1024 matrix. Materials and methods: Four CT image types were reconstructed: type A (512 × 512 matrix, 1-mm slice thickness), type B (1024 × 1024 matrix, 1-mm slice thickness), type C (1024 × 1024 matrix, 0.5-mm slice thickness), and type D (retargeted zoomed images; 512 × 512 matrix, 1-mm slice thickness). Type D images served as the reference standard with a field of view (FOV) half that of the other image types. Phantom image quality was objectively assessed using the task transfer function (TTF), noise power spectrum (NPS), and attenuation profile analysis. In the clinical study, two radiologists independently evaluated image quality in 93 patients, including abnormal lung findings, normal structures, and subjective image noise. Results: In the phantom study, post-processing 1024 × 1024 matrix reconstruction derived from the same sinogram as conventional 512 × 512 reconstruction improved spatial resolution while maintaining comparable noise characteristics at the same slice thickness. Clinically, image quality of normal structures and abnormal lesions was significantly higher in the order of type C > type B > type A (p < 0.0001). Subjective image noise followed the same order. Image quality and noise levels of type B images were comparable to those of type D images. Conclusion: Post-processing 1024 × 1024 matrix reconstruction improves spatial resolution and provides clinically useful high-resolution CT images comparable to retargeted zoomed reconstruction without the limitation of a reduced FOV.

Original languageEnglish
Pages (from-to)1159-1167
Number of pages9
JournalJapanese Journal of Radiology
Volume44
Issue number7
DOIs
Publication statusPublished - 07-2026

All Science Journal Classification (ASJC) codes

  • Radiology Nuclear Medicine and imaging

Fingerprint

Dive into the research topics of 'High-resolution chest CT using 1024-matrix reconstruction: phantom and clinical evaluation of image quality and post-processing capability'. Together they form a unique fingerprint.

Cite this