Impact of a novel biopsy instrument with a 25-mm side-notch needle on the detection of prostate cancer in transrectal biopsy

  • Kent Kanao
  • , Keishi Kajikawa
  • , Ikuo Kobayashi
  • , Shingo Morinaga
  • , Hiroyuki Muramatsu
  • , Genya Nishikawa
  • , Masahito Watanabe
  • , Kenji Zennami
  • , Kogenta Nakamura
  • , Makoto Sumitomo

Research output: Contribution to journalArticlepeer-review

Abstract

Objectives: To evaluate the impact of a novel biopsy instrument that extends the length of the side-notch on the detection of prostate cancer in transrectal needle biopsy. Methods: We collaborated with a biopsy needle manufacturer and developed a novel biopsy instrument (PRIMECUT II long-notch type) with a 25-mm side-notch length and 28-mm stroke length to take longer tissue cores. The sampled core length, cancer detection rate, pain and complications of 489 patients who underwent transrectal biopsy using the long-notch needle were compared with those of 469 patients who underwent biopsy using a normal instrument with a 19-mm side-notch length and 22-mm stroke length. Results: The mean length of tissue taken by the long-notch needle was significantly longer than that of tissue taken by the normal-notch needle (16.3 vs 22.4 mm, P < 0.001). The overall cancer detection rate was 42.0% for the normal-notch needle and 51.1% for the long-notch needle (P = 0.005). In patients with a prostate volume of 20–40 mL, the cancer detection rate for the long-notch needle was especially higher than that for the normal-notch needle (74.2% vs 47.5%, P < 0.001). Multivariate analysis showed that the long-notch needle improved cancer detection significantly (odds ratio 1.702, P < 0.001). There were no differences of pain during biopsy and complication between the two groups. Conclusions: The novel biopsy instrument with a 25-mm side-notch can take longer tissue samples safely and has a significantly higher rate of prostate cancer detection in transrectal biopsy.

Original languageEnglish
Pages (from-to)746-751
Number of pages6
JournalInternational Journal of Urology
Volume25
Issue number8
DOIs
Publication statusPublished - 08-2018
Externally publishedYes

UN SDGs

This output contributes to the following UN Sustainable Development Goals (SDGs)

  1. SDG 3 - Good Health and Well-being
    SDG 3 Good Health and Well-being

All Science Journal Classification (ASJC) codes

  • Urology

Fingerprint

Dive into the research topics of 'Impact of a novel biopsy instrument with a 25-mm side-notch needle on the detection of prostate cancer in transrectal biopsy'. Together they form a unique fingerprint.

Cite this