Skip to main navigation Skip to search Skip to main content

Long-Term Prognosis and Outcomes in Patients Undergoing His Bundle Pacing Implantation ― A Multicenter, Prospective Observational Study in Japan ―

  • Satoshi Yanagisawa
  • , Hiroyuki Kato
  • , Yasunori Kanzaki
  • , Yosuke Murase
  • , Masaya Fujita
  • , Toshifumi Nakagomi
  • , Shinji Ishikawa
  • , Yosuke Kamikubo
  • , Hirohiko Suzuki
  • , Hisashi Murakami
  • , Itsuro Morishima
  • , Hajime Imai
  • , Shinji Kaneko
  • , Yukihiko Yoshida
  • , Takahiro Okumura
  • , Rei Shibata
  • , Yasuya Inden
  • , Toyoaki Murohara

Research output: Contribution to journal › Article › peer-review

Abstract

Background: His bundle (HB) pacing (HBP) can achieve an ideal pattern of ventricular activation. The long-term efficacy and clinical outcomes of HBP in Japan remain unclear. Methods and Results: This multicenter prospective observational study enrolled 115 patients undergoing HBP implantation at 8 experienced centers in Japan. Inclusion criteria comprised atrioventricular block or conduction disturbance and an anticipated ventricular pacing of ≥40% in patients scheduled for HBP implantation. All patients were followed for 3 years after implantation. The primary endpoints were all-cause mortality, hospitalization for heart failure, and upgrade to cardiac resynchronization therapy. Secondary endpoints were changes in echocardiographic parameters and laboratory biomarkers after implantation. Seventy-eight (68%) patients continued HBP after the procedure (procedural success), whereas 68 (59%) patients exhibited clinical success (HB capture threshold ≤2.5 V at 1.0 ms). Six months after implantation, echocardiographic parameters improved, and brain B-type natriuretic peptide (BNP) levels decreased substantially. Major adverse clinical events (MACE), defined as the composite of the primary endpoints, occurred in 16 (21%) patients; 18 (23%) patients discontinued HBP during the follow-up period. Multivariable analysis identified elevated BNP levels at baseline as an independent predictor of MACE. Conclusions: HBP implantation presents technical challenges and exhibits a moderate success rate in real-world clinical practice. The high incidence of elevated HB capture thresholds and HBP abandonment mean that careful patient selection and rigorous long-term surveillance are required.

Original languageEnglish
Pages (from-to)871-880
Number of pages10
JournalCirculation Journal
Volume90
Issue number7
DOIs
Publication statusPublished - 07-2026
Externally publishedYes

All Science Journal Classification (ASJC) codes

  • Cardiology and Cardiovascular Medicine

Fingerprint

Dive into the research topics of 'Long-Term Prognosis and Outcomes in Patients Undergoing His Bundle Pacing Implantation ― A Multicenter, Prospective Observational Study in Japan ―'. Together they form a unique fingerprint.

Cite this