TY - JOUR
T1 - Long-term prognostic factors of chronic central serous chorioretinopathy after half-dose photodynamic therapy
T2 - A 3-year followup study
AU - Haga, Fuminori
AU - Maruko, Ruka
AU - Sato, Chiaki
AU - Kataoka, Keiko
AU - Ito, Yasuki
AU - Terasaki, Hiroko
N1 - Publisher Copyright:
© 2017 Haga et al. This is an open access article distributed under the terms of the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are credited.
PY - 2017/7
Y1 - 2017/7
N2 - Purpose: To evaluate the long-term efficacy and factors involved in the recurrence and persistence of subretinal fluid (SRF) after half-dose photodynamic therapy (PDT) for chronic central serous chorioretinopathy (CSC). Methods: In this retrospective observational case series, 79 eyes (73 patients) with chronic CSC were treated with half-dose PDT and followed up for at least 3 years. They were divided into successful (64 eyes) and unsuccessful (15 eyes) groups based on SRF absorption and disease recurrence after one PDT session. Age, best-corrected visual acuity (BCVA), central foveal thickness, neuroretinal thickness, height of SRF, subfoveal choroidal thickness, window defect area detected by fluorescein angiography, and PDT spot area were compared between the groups. Factors associated with PDT success and BCVA at 3 years were investigated. Results: LogMAR BCVA improved from 0.21±0.24 to 0.08±0.16 (P<0.001) at 3 years after PDT. Compared with the unsuccessful group, the successful group had a significantly younger mean age (50.5±9.7 vs. 56.5±9.1 years, P = 0.032) and better baseline BCVA (0.18±0.23 vs. 0.32±0.25, P = 0.034). Other parameters were not significantly different. Multivariate analyses showed that unsuccessful PDT was significantly associated with lower baseline BCVA (P = 0.026) and older age (P = 0.029) and that BCVA at 3 years after PDT was positively associated with baseline BCVA (P<0.001). Conclusions: Half-dose PDT has a long-term efficacy in chronic CSC. Relatively early PDT may improve anatomic and functional outcomes of chronic CSC.
AB - Purpose: To evaluate the long-term efficacy and factors involved in the recurrence and persistence of subretinal fluid (SRF) after half-dose photodynamic therapy (PDT) for chronic central serous chorioretinopathy (CSC). Methods: In this retrospective observational case series, 79 eyes (73 patients) with chronic CSC were treated with half-dose PDT and followed up for at least 3 years. They were divided into successful (64 eyes) and unsuccessful (15 eyes) groups based on SRF absorption and disease recurrence after one PDT session. Age, best-corrected visual acuity (BCVA), central foveal thickness, neuroretinal thickness, height of SRF, subfoveal choroidal thickness, window defect area detected by fluorescein angiography, and PDT spot area were compared between the groups. Factors associated with PDT success and BCVA at 3 years were investigated. Results: LogMAR BCVA improved from 0.21±0.24 to 0.08±0.16 (P<0.001) at 3 years after PDT. Compared with the unsuccessful group, the successful group had a significantly younger mean age (50.5±9.7 vs. 56.5±9.1 years, P = 0.032) and better baseline BCVA (0.18±0.23 vs. 0.32±0.25, P = 0.034). Other parameters were not significantly different. Multivariate analyses showed that unsuccessful PDT was significantly associated with lower baseline BCVA (P = 0.026) and older age (P = 0.029) and that BCVA at 3 years after PDT was positively associated with baseline BCVA (P<0.001). Conclusions: Half-dose PDT has a long-term efficacy in chronic CSC. Relatively early PDT may improve anatomic and functional outcomes of chronic CSC.
UR - http://www.scopus.com/inward/record.url?scp=85025167375&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=85025167375&partnerID=8YFLogxK
U2 - 10.1371/journal.pone.0181479
DO - 10.1371/journal.pone.0181479
M3 - Article
C2 - 28742138
AN - SCOPUS:85025167375
SN - 1932-6203
VL - 12
JO - PloS one
JF - PloS one
IS - 7
M1 - e0181479
ER -