TY - JOUR
T1 - Measurements of the doses of eye lens for the workers of Fukushima Daiichi Nuclear Power Plant
AU - Yokoyama, Sumi
AU - Ezaki, Iwao
AU - Tatsuzaki, Hideo
AU - Tachiki, Shuichi
AU - Hirao, Shigekazu
AU - Aoki, Katsunori
AU - Tanimura, Yoshihiko
AU - Hoshi, Katsuya
AU - Yoshitomi, Hiroshi
AU - Tsujimura, Norio
N1 - Publisher Copyright:
© 2020 Elsevier Ltd
PY - 2020/11
Y1 - 2020/11
N2 - In Japan, the possibility to change the current dose limit of the lens of the eye for the radiation workers working in the planned exposure situation (normal controlled situations) to a new ICRP dose limit was discussed. It was further discussed how to appropriately monitor and manage the equivalent dose of the eye lenses for these workers exposed to radiation at their workplaces, such as nuclear and medical facilities. Among the workers exposed to a high-dose radiation at the water storage flange tank deconstructed 90Sr/90Y dominant areas and the nuclear reactor buildings (high dose gamma-ray) of the Fukushima Daiichi Nuclear Power Plant (1F-NPP), Hp(10), Hp(3), and Hp(0.07) at the head and the chest (or the upper arm) were estimated by passive personal dosimeters using thermoluminescence dosimeters (TLDs) and radio photoluminescence glass dosimeters (RPLGDs). The relationship between Hp(10), Hp(3), and Hp(0.07) along with the effects of the sites of wearing dosimeters on the head inside a full-face mask and the chest (or upper arm) were discussed.
AB - In Japan, the possibility to change the current dose limit of the lens of the eye for the radiation workers working in the planned exposure situation (normal controlled situations) to a new ICRP dose limit was discussed. It was further discussed how to appropriately monitor and manage the equivalent dose of the eye lenses for these workers exposed to radiation at their workplaces, such as nuclear and medical facilities. Among the workers exposed to a high-dose radiation at the water storage flange tank deconstructed 90Sr/90Y dominant areas and the nuclear reactor buildings (high dose gamma-ray) of the Fukushima Daiichi Nuclear Power Plant (1F-NPP), Hp(10), Hp(3), and Hp(0.07) at the head and the chest (or the upper arm) were estimated by passive personal dosimeters using thermoluminescence dosimeters (TLDs) and radio photoluminescence glass dosimeters (RPLGDs). The relationship between Hp(10), Hp(3), and Hp(0.07) along with the effects of the sites of wearing dosimeters on the head inside a full-face mask and the chest (or upper arm) were discussed.
UR - http://www.scopus.com/inward/record.url?scp=85089939371&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=85089939371&partnerID=8YFLogxK
U2 - 10.1016/j.radmeas.2020.106399
DO - 10.1016/j.radmeas.2020.106399
M3 - Article
AN - SCOPUS:85089939371
SN - 1350-4487
VL - 138
JO - Radiation Measurements
JF - Radiation Measurements
M1 - 106399
ER -