Midterm results for endovascular stent grafts via median sternotomy for distal aortic arch aneurysm

Koji Sakurai, Akihiko Usui, Yuuichi Ueda, Toshiaki Akita, Masaharu Yoshikawa, Hiroomi Murayama, Tsuneo Ishiguchi, Kazuki Tajima

Research output: Contribution to journalArticlepeer-review

5 Citations (Scopus)

Abstract

Dislocation or perigraft leakage is a major problem during the follow-up period for endovascular stent graft (EVG) implantation via median sternotomy for distal aortic arch aneurysm. Anchoring sutures have been applied for the prevention of these complications. Here, we evaluate the midterm results and the efficacy of anchoring sutures. There were 21 male and 2 female patients enrolled in the study with an average age of 70 years (59-83). Aneurysm types were 21 true aneurysms (13 fusiform, 8 saccular), 1 chronic dissection, and 1 penetrating aortic ulcer. Total arch replacement was performed in two patients and aortocoronary bypass grafting was combined in four patients. Anchoring sutures to fix the EVG via median sternotomy were applied for 11 recent patients. The average follow-up period was 44 (22-79) months. There were no operative mortalities, but one case of paraplegia, one of stroke, and two of temporary spinal cord dysfunction. Complications related to EVG via median sternotomy occurred in five patients who had not received anchoring sutures, but the 11 patients with anchoring sutures showed no EVG-related complications. A chronic type B dissection revealed impending rupture due to false lumen infection 1 year after operation and repeat surgery was performed. Stent dislocation occurred in four patients, two of whom required repeat surgery via left thoracotomy due to endoleakage 3 and 4 years after surgery. One died from aneurismal rupture 5 years after surgery. One required emergency graft replacement because of graft perforation 5 years after surgery. The proportion of patients free from EVG-related events at 5 years after surgery was 75%. Anchoring sutures (P = 0.0155) and a large aneurysm of more than 80 mm (P = 0.0190) were predictors of late EVG-related complications. There were five late deaths: two were from stroke, one from rupture, one from cancer, and one from multiple organ failure after repeat surgery. EVG shortens postoperative recovery with relatively lower mortality, but spinal cord injury is a complication occurring with a relatively high rate. Patients with large aneurysms are not good candidates for EVG implantation via median sternotomy Anchoring sutures to fix the EVG to the aortic wall should help prevent EVG-related events and improve the durability of EVG.

Original languageEnglish
Pages (from-to)149-153
Number of pages5
JournalJournal of Artificial Organs
Volume9
Issue number3
DOIs
Publication statusPublished - 09-2006
Externally publishedYes

All Science Journal Classification (ASJC) codes

  • Medicine (miscellaneous)
  • Biomaterials
  • Biomedical Engineering
  • Cardiology and Cardiovascular Medicine

Fingerprint

Dive into the research topics of 'Midterm results for endovascular stent grafts via median sternotomy for distal aortic arch aneurysm'. Together they form a unique fingerprint.

Cite this