TY - JOUR
T1 - Mitral valve replacement with homemade heterologous pericardial roll valve for mitral regurgitation after repair of complete atrioventricular septal defect
AU - Maeda, M.
AU - Takemura, H.
AU - Iwase, J.
AU - Sai, N.
AU - Usui, A.
AU - Kanamoto, I.
PY - 1995/11
Y1 - 1995/11
N2 - Repair of using the double patch method was performed on a 6-month old child with Down's syndrome. However, at 1 year and 4 months (BW: 3.6 kg), the patient's resulting mitral regurgitation became severe and clinically unmanageable, necessitating further operation. At operation the anterior leaflet of the mitral valve was lifted up at the anterolateral side due to the patch attached to the interventricular septum, which restricted the valve from closing completely. Moreover, secondary severe hardening of the valve tissue made it difficult to reconstruct the valve. Since the diameter of the valve was only 13 mm after resection, making the impossible use of a standard prosthetic valve, we constructed a new roll valve out of a heterologous pericardium. Almost no regurgitation was observed and prognosis was favorable although a pattern of mitral stenosis was observed. The patient died 6 months later due to the worsening of respiratory infection before a reoperation could be performed. Post mortem examination revealed comparatively good valve function except mitral stenosis due to inadequate valve size. This technique has practical application for mitral valve replacement of small valve annuli of infants when other methods are not feasible.
AB - Repair of using the double patch method was performed on a 6-month old child with Down's syndrome. However, at 1 year and 4 months (BW: 3.6 kg), the patient's resulting mitral regurgitation became severe and clinically unmanageable, necessitating further operation. At operation the anterior leaflet of the mitral valve was lifted up at the anterolateral side due to the patch attached to the interventricular septum, which restricted the valve from closing completely. Moreover, secondary severe hardening of the valve tissue made it difficult to reconstruct the valve. Since the diameter of the valve was only 13 mm after resection, making the impossible use of a standard prosthetic valve, we constructed a new roll valve out of a heterologous pericardium. Almost no regurgitation was observed and prognosis was favorable although a pattern of mitral stenosis was observed. The patient died 6 months later due to the worsening of respiratory infection before a reoperation could be performed. Post mortem examination revealed comparatively good valve function except mitral stenosis due to inadequate valve size. This technique has practical application for mitral valve replacement of small valve annuli of infants when other methods are not feasible.
UR - http://www.scopus.com/inward/record.url?scp=0029397175&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=0029397175&partnerID=8YFLogxK
M3 - Article
C2 - 8522876
AN - SCOPUS:0029397175
SN - 0369-4739
VL - 43
SP - 1870
EP - 1874
JO - [Zasshi] [Journal]. Nihon Kyōbu Geka Gakkai
JF - [Zasshi] [Journal]. Nihon Kyōbu Geka Gakkai
IS - 11
ER -