Multi-lead ambulatory electrocardiograph for recording body surface ST maps in daily life

T. Yasui, S. Suzuki, M. Okajima

Research output: Contribution to journalReview article

Abstract

We attempted to construct ambulatory body surface isopotential maps of ST segment using our newly designed multi-lead ambulatory electrocardiograph. The multi-lead ambulatory electrocardiograph. The multi-lead ambulatory ECG system consisted of a commercially-available 4-channel recorder and a specially designed adapter, by which 30-lead ECGs were recorded together with body position signals for 24 hours. The electrode positions were selected from the 87 lead points for body surface mapping according to Yamada et al. Compensation for ST distortion and interpolation of ST level on time scale techniques were performed before the construction of ST maps. The extension and location of ST depression area thus obtained after compensation and interpolation were thought to be reasonable. In conclusion, the ambulatory recording of body surface ST maps is possible using our new device and may become useful for study of myocardial ischemia in daily life.

Original languageEnglish
Pages (from-to)92-97
Number of pages6
JournalNippon rinsho. Japanese journal of clinical medicine
Volume53
Issue number1
Publication statusPublished - 01-01-1995

Fingerprint

Electrocardiography
Body Surface Potential Mapping
Myocardial Ischemia
Electrodes
Equipment and Supplies
Lead

All Science Journal Classification (ASJC) codes

  • Medicine(all)

Cite this

@article{5f54c2e953344d41a31630760942600b,
title = "Multi-lead ambulatory electrocardiograph for recording body surface ST maps in daily life",
abstract = "We attempted to construct ambulatory body surface isopotential maps of ST segment using our newly designed multi-lead ambulatory electrocardiograph. The multi-lead ambulatory electrocardiograph. The multi-lead ambulatory ECG system consisted of a commercially-available 4-channel recorder and a specially designed adapter, by which 30-lead ECGs were recorded together with body position signals for 24 hours. The electrode positions were selected from the 87 lead points for body surface mapping according to Yamada et al. Compensation for ST distortion and interpolation of ST level on time scale techniques were performed before the construction of ST maps. The extension and location of ST depression area thus obtained after compensation and interpolation were thought to be reasonable. In conclusion, the ambulatory recording of body surface ST maps is possible using our new device and may become useful for study of myocardial ischemia in daily life.",
author = "T. Yasui and S. Suzuki and M. Okajima",
year = "1995",
month = "1",
day = "1",
language = "English",
volume = "53",
pages = "92--97",
journal = "Nippon rinsho. Japanese journal of clinical medicine",
issn = "0047-1852",
publisher = "Nipponrinsho Co., Inc.",
number = "1",

}

Multi-lead ambulatory electrocardiograph for recording body surface ST maps in daily life. / Yasui, T.; Suzuki, S.; Okajima, M.

In: Nippon rinsho. Japanese journal of clinical medicine, Vol. 53, No. 1, 01.01.1995, p. 92-97.

Research output: Contribution to journalReview article

TY - JOUR

T1 - Multi-lead ambulatory electrocardiograph for recording body surface ST maps in daily life

AU - Yasui, T.

AU - Suzuki, S.

AU - Okajima, M.

PY - 1995/1/1

Y1 - 1995/1/1

N2 - We attempted to construct ambulatory body surface isopotential maps of ST segment using our newly designed multi-lead ambulatory electrocardiograph. The multi-lead ambulatory electrocardiograph. The multi-lead ambulatory ECG system consisted of a commercially-available 4-channel recorder and a specially designed adapter, by which 30-lead ECGs were recorded together with body position signals for 24 hours. The electrode positions were selected from the 87 lead points for body surface mapping according to Yamada et al. Compensation for ST distortion and interpolation of ST level on time scale techniques were performed before the construction of ST maps. The extension and location of ST depression area thus obtained after compensation and interpolation were thought to be reasonable. In conclusion, the ambulatory recording of body surface ST maps is possible using our new device and may become useful for study of myocardial ischemia in daily life.

AB - We attempted to construct ambulatory body surface isopotential maps of ST segment using our newly designed multi-lead ambulatory electrocardiograph. The multi-lead ambulatory electrocardiograph. The multi-lead ambulatory ECG system consisted of a commercially-available 4-channel recorder and a specially designed adapter, by which 30-lead ECGs were recorded together with body position signals for 24 hours. The electrode positions were selected from the 87 lead points for body surface mapping according to Yamada et al. Compensation for ST distortion and interpolation of ST level on time scale techniques were performed before the construction of ST maps. The extension and location of ST depression area thus obtained after compensation and interpolation were thought to be reasonable. In conclusion, the ambulatory recording of body surface ST maps is possible using our new device and may become useful for study of myocardial ischemia in daily life.

UR - http://www.scopus.com/inward/record.url?scp=0029180869&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=0029180869&partnerID=8YFLogxK

M3 - Review article

C2 - 7897862

AN - SCOPUS:0029180869

VL - 53

SP - 92

EP - 97

JO - Nippon rinsho. Japanese journal of clinical medicine

JF - Nippon rinsho. Japanese journal of clinical medicine

SN - 0047-1852

IS - 1

ER -