Natural history of optical coherence tomography-detected non-flow-limiting edge dissections following drug-eluting stent implantation

Maria D. Radu, Lorenz Räber, Jungho Heo, Bill D. Gogas, Erik Jørgensen, Henning Kelbæk, Takashi Muramatsu, Vasim Farooq, Steffen Helqvist, Hector M. Garcia-Garcia, Stephan Windecker, Kari Saunamäki, Patrick W. Serruys

Research output: Contribution to journalArticlepeer-review

81 Citations (Scopus)

Abstract

Aims: Angiographic evidence of edge dissections has been associated with a risk of early stent thrombosis. Optical coherence tomography (OCT) is a high-resolution technology detecting a greater number of edge dissections - particularly non-flow-limiting - compared to angiography. Their natural history and clinical implications remain unclear. The objectives of the present study were to assess the morphology, healing response, and clinical outcomes of OCT-detected edge dissections using serial OCT imaging at baseline and at one year following drug-eluting stent (DES) implantation. Methods and results: Edge dissections were defined as disruptions of the luminal surface in the 5 mm segments proximal and distal to the stent, and categorised as flaps, cavities, double-lumen dissections or fissures. Qualitative and quantitative OCT analyses were performed every 0.5 mm at baseline and one year, and clinical outcomes were assessed. Sixty-three lesions (57 patients) were studied with OCT at baseline and one-year follow-up. Twenty-two non-flow-limiting edge dissections in 21 lesions (20 patients) were identified by OCT; only two (9%) were angiographically visible. Flaps were found in 96% of cases. The median longitudinal dissection length was 2.9 mm (interquartile range [IQR] 1.6-4.2 mm), whereas the circumferential and axial extensions amounted to 1.2 mm (IQR: 0.9-1.7 mm) and 0.6 mm (IQR: 0.4-0.7 mm), respectively. Dissections extended into the media and adventitia in seven (33%) and four (20%) cases, respectively. Eighteen (82%) OCT-detected edge dissections were also evaluated with intravascular ultrasound which identified nine (50%) of these OCT-detected dissections. No stent thrombosis or target lesion revascularisation occurred up to one year. At follow-up, 20 (90%) edge dissections were completely healed on OCT. The two cases exhibiting persistent dissection had the longest flaps (2.81 mm and 2.42 mm) at baseline. Conclusions: OCT-detected edge dissections which are angiographically silent in the majority of cases are not associated with acute stent thrombosis or restenosis up to one-year follow-up.

Original languageEnglish
Pages (from-to)1085-1094
Number of pages10
JournalEuroIntervention
Volume9
Issue number9
DOIs
Publication statusPublished - 01-2014
Externally publishedYes

All Science Journal Classification (ASJC) codes

  • Cardiology and Cardiovascular Medicine

Fingerprint

Dive into the research topics of 'Natural history of optical coherence tomography-detected non-flow-limiting edge dissections following drug-eluting stent implantation'. Together they form a unique fingerprint.

Cite this