TY - JOUR
T1 - Non-small cell carcinoma
T2 - Comparison of postoperative intra- and extrathoracic recurrence assessment capability of qualitatively and/or quantitatively assessed FDG-PET/CT and standard radiological examinations
AU - Onishi, Yumiko
AU - Ohno, Yoshiharu
AU - Koyama, Hisanobu
AU - Nogami, Munenobu
AU - Takenaka, Daisuke
AU - Matsumoto, Keiko
AU - Yoshikawa, Takeshi
AU - Matsumoto, Sumiaki
AU - Maniwa, Yoshimasa
AU - Nishimura, Yoshihiro
AU - Sugimura, Kazuro
PY - 2011/9
Y1 - 2011/9
N2 - Purpose: The purpose of this study was to compare the capability of integrated FDG-PET/CT for assessment of postoperative intra- and extrathoracic recurrence in non-small cell lung cancer (NSCLC) patients with that of standard radiological examinations. Materials and methods: A total of 121 consecutive pathologically diagnosed NSCLC patients (80 males, 41 females; mean age, 71 years) underwent pathologically and surgically confirmed complete resection, followed by prospective integrated FDG-PET/CT and standard radiological examinations. Final diagnosis of recurrence was based on the results of more than 12 months of follow-up and/or pathological examinations. The probability of recurrence was assessed with either method for each patient by using 5-point visual scoring system, and final diagnosis was made by consensus between two readers. ROC analysis was used to compare the capability of the two methods for assessment of postoperative recurrence on a per-patient basis. The ROC-based positive test was used to determine optimal cut-off value for FDG uptake measurement at a site suspected on the basis of qualitatively assessed PET/CT. Finally, sensitivities, specificities and accuracies of all methods were compared by means of McNemar's test. Results: Areas under the curve of qualitatively assessed PET/CT and standard radiological examinations showed no significant differences (p > 0.05). At an optimal cut-off value of 2.5, specificity and accuracy of quantitatively and qualitatively assessed PET/CT were significantly higher than those of qualitatively assessed PET/CT and standard radiological examinations (p < 0.05). Conclusion: Accuracy of assessment of postoperative intra- and extrathoracic recurrence in NSCLC patients by qualitative and/or quantitative FDG-PET/CT is equivalent to or higher than that by standard radiological examinations.
AB - Purpose: The purpose of this study was to compare the capability of integrated FDG-PET/CT for assessment of postoperative intra- and extrathoracic recurrence in non-small cell lung cancer (NSCLC) patients with that of standard radiological examinations. Materials and methods: A total of 121 consecutive pathologically diagnosed NSCLC patients (80 males, 41 females; mean age, 71 years) underwent pathologically and surgically confirmed complete resection, followed by prospective integrated FDG-PET/CT and standard radiological examinations. Final diagnosis of recurrence was based on the results of more than 12 months of follow-up and/or pathological examinations. The probability of recurrence was assessed with either method for each patient by using 5-point visual scoring system, and final diagnosis was made by consensus between two readers. ROC analysis was used to compare the capability of the two methods for assessment of postoperative recurrence on a per-patient basis. The ROC-based positive test was used to determine optimal cut-off value for FDG uptake measurement at a site suspected on the basis of qualitatively assessed PET/CT. Finally, sensitivities, specificities and accuracies of all methods were compared by means of McNemar's test. Results: Areas under the curve of qualitatively assessed PET/CT and standard radiological examinations showed no significant differences (p > 0.05). At an optimal cut-off value of 2.5, specificity and accuracy of quantitatively and qualitatively assessed PET/CT were significantly higher than those of qualitatively assessed PET/CT and standard radiological examinations (p < 0.05). Conclusion: Accuracy of assessment of postoperative intra- and extrathoracic recurrence in NSCLC patients by qualitative and/or quantitative FDG-PET/CT is equivalent to or higher than that by standard radiological examinations.
UR - http://www.scopus.com/inward/record.url?scp=80052267559&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=80052267559&partnerID=8YFLogxK
U2 - 10.1016/j.ejrad.2010.04.027
DO - 10.1016/j.ejrad.2010.04.027
M3 - Article
C2 - 20547021
AN - SCOPUS:80052267559
SN - 0720-048X
VL - 79
SP - 473
EP - 479
JO - European journal of radiology
JF - European journal of radiology
IS - 3
ER -