T1 - Objective assessment of leg edema using ultrasonography with a gel pad
AU - Iuchi, Terumi
AU - Kobayashi, Masato
AU - Tsuchiya, Sayumi
AU - Ohno, Naoki
AU - Dai, Misako
AU - Matsumoto, Masaru
AU - Ogai, Kazuhiro
AU - Sato, Aya
AU - Sawazaki, Takuto
AU - Miyati, Tosiaki
AU - Tanaka, Shinobu
AU - Sugama, Junko
N1 - Publisher Copyright:
© 2017 Iuchi et al.
PY - 2017/8
Y1 - 2017/8
N2 - Ultrasonography (US) is useful for visual detection of edematous tissues to assess subcutaneous echogenicity. However, visualization of subcutaneous echogenicity is interpreted differently among operators because the evaluation is subjective and individual operators have unique knowledge. This study objectively assessed leg edema using US with a gel pad including fat for normalization of echogenicity in subcutaneous tissue. Five younger adults and four elderly people with leg edema were recruited. We compared assessments of US and limb circumference before and after the intervention of vibration to decrease edema in younger adults, and edema prior to going to sleep and reduced edema in the early morning in elderly people. These assessments were performed twice in elderly people by three operators and reliability, interrater differences, and bias were assessed. For US assessment, echogenicity in subcutaneous tissue was normalized to that of the gel pad by dividing the mean echogenicity of subcutaneous tissue by the mean echogenicity of the gel pad. In younger adults, the normalized subcutaneous echogenicity before the intervention was significantly higher than that after the intervention. In elderly people, echogenicity indicating edema was significantly higher than that after edema reduction. Edema was detected with accuracy rates of 76.9% in younger adults and 75.0% in elderly people. Meanwhile, limb circumference could be used to detect edema in 50.0% of healthy adults and 87.8% of elderly people. The intra-reliability was excellent (intraclass correlation coefficient > 0.9, p < 0.01), and the interreliability was good (intraclass correlation coefficient > 0.7, p < 0.01) for normalized subcutaneous echogenicity. Bland-Altman plots revealed that inter-rater differences and systematic bias were small. Normalized subcutaneous echogenicity with the pad can sensitively and objectively assess leg edema with high reliability. Therefore, this method has the potential to become a new gold standard for objective assessment of leg edema in clinical practice.
AB - Ultrasonography (US) is useful for visual detection of edematous tissues to assess subcutaneous echogenicity. However, visualization of subcutaneous echogenicity is interpreted differently among operators because the evaluation is subjective and individual operators have unique knowledge. This study objectively assessed leg edema using US with a gel pad including fat for normalization of echogenicity in subcutaneous tissue. Five younger adults and four elderly people with leg edema were recruited. We compared assessments of US and limb circumference before and after the intervention of vibration to decrease edema in younger adults, and edema prior to going to sleep and reduced edema in the early morning in elderly people. These assessments were performed twice in elderly people by three operators and reliability, interrater differences, and bias were assessed. For US assessment, echogenicity in subcutaneous tissue was normalized to that of the gel pad by dividing the mean echogenicity of subcutaneous tissue by the mean echogenicity of the gel pad. In younger adults, the normalized subcutaneous echogenicity before the intervention was significantly higher than that after the intervention. In elderly people, echogenicity indicating edema was significantly higher than that after edema reduction. Edema was detected with accuracy rates of 76.9% in younger adults and 75.0% in elderly people. Meanwhile, limb circumference could be used to detect edema in 50.0% of healthy adults and 87.8% of elderly people. The intra-reliability was excellent (intraclass correlation coefficient > 0.9, p < 0.01), and the interreliability was good (intraclass correlation coefficient > 0.7, p < 0.01) for normalized subcutaneous echogenicity. Bland-Altman plots revealed that inter-rater differences and systematic bias were small. Normalized subcutaneous echogenicity with the pad can sensitively and objectively assess leg edema with high reliability. Therefore, this method has the potential to become a new gold standard for objective assessment of leg edema in clinical practice.
UR - http://www.scopus.com/inward/record.url?scp=85030612069&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=85030612069&partnerID=8YFLogxK
U2 - 10.1371/journal.pone.0182042
DO - 10.1371/journal.pone.0182042
M3 - Article
C2 - 28792959
AN - SCOPUS:85030612069
SN - 1932-6203
VL - 12
JO - PloS one
JF - PloS one
IS - 8
M1 - e0182042
ER -