TY - JOUR
T1 - Paracorporeal ventricular assist device as a bridge to transplant candidacy in the era of implantable continuous-flow ventricular assist device
AU - Suwa, Hideaki
AU - Seguchi, Osamu
AU - Fujita, Tomoyuki
AU - Murata, Yoshihiro
AU - Hieda, Michinari
AU - Watanabe, Takuya
AU - Sato, Takuma
AU - Sunami, Haruki
AU - Yanase, Masanobu
AU - Hata, Hiroki
AU - Nakatani, Takeshi
PY - 2014/3
Y1 - 2014/3
N2 - Ventricular assist devices (VADs) have long been used as bridge to transplant therapy (BTT). Nipro-Toyobo paracorporeal pulsatile-flow VAD (nt-VAD) was the only device available until April 2011, when implantable continuous-flow VADs (cf-VADs) became available. Although cf-VADs are central to BTT, nt-VAD remains a necessary option. We aimed to clarify the role of nt-VAD in an era of increasing cf-VAD use. We retrospectively reviewed patients who underwent VAD implantation at the National Cerebral and Cardiovascular Center from May 2011 to March 2013. Characteristics were compared between the nt-VAD and cf-VAD groups. Twenty-nine patients (mean age 37.7 ± 11.1 years, 23 males) underwent VAD implantation. Fifteen patients initially received nt-VADs, although 4 were converted to cf-VADs. Of these 15 patients, 3 were too small for cf-VADs and 2 needed bilateral ventricular support. The remaining 10 patients received nt-VADs (7 patients at INTERMACS level 1 and 3 at level 2). The nt-VAD group patients had significantly more preoperative mechanical circulatory support and were in a more critical condition before VAD implantation than the cf-VAD group. The 2-year survival rate was not significantly different. Despite the critical conditions of nt-VAD patients, their overall survival is not statistically inferior to that of cf-VAD patients. nt-VAD is a good option as a BTC for the patient with urgent and critical condition.
AB - Ventricular assist devices (VADs) have long been used as bridge to transplant therapy (BTT). Nipro-Toyobo paracorporeal pulsatile-flow VAD (nt-VAD) was the only device available until April 2011, when implantable continuous-flow VADs (cf-VADs) became available. Although cf-VADs are central to BTT, nt-VAD remains a necessary option. We aimed to clarify the role of nt-VAD in an era of increasing cf-VAD use. We retrospectively reviewed patients who underwent VAD implantation at the National Cerebral and Cardiovascular Center from May 2011 to March 2013. Characteristics were compared between the nt-VAD and cf-VAD groups. Twenty-nine patients (mean age 37.7 ± 11.1 years, 23 males) underwent VAD implantation. Fifteen patients initially received nt-VADs, although 4 were converted to cf-VADs. Of these 15 patients, 3 were too small for cf-VADs and 2 needed bilateral ventricular support. The remaining 10 patients received nt-VADs (7 patients at INTERMACS level 1 and 3 at level 2). The nt-VAD group patients had significantly more preoperative mechanical circulatory support and were in a more critical condition before VAD implantation than the cf-VAD group. The 2-year survival rate was not significantly different. Despite the critical conditions of nt-VAD patients, their overall survival is not statistically inferior to that of cf-VAD patients. nt-VAD is a good option as a BTC for the patient with urgent and critical condition.
UR - http://www.scopus.com/inward/record.url?scp=84896909949&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=84896909949&partnerID=8YFLogxK
U2 - 10.1007/s10047-013-0731-3
DO - 10.1007/s10047-013-0731-3
M3 - Article
C2 - 24096597
AN - SCOPUS:84896909949
SN - 1434-7229
VL - 17
SP - 16
EP - 22
JO - Journal of Artificial Organs
JF - Journal of Artificial Organs
IS - 1
ER -