TY - JOUR
T1 - Plain radiograph evaluation of concurrent filling of tibial peg holes with bone in cementless total knee arthroplasty
AU - Hayakawa, Kazue
AU - Date, Hideki
AU - Nojiri, Sho
AU - Kaneko, Yosuke
AU - Shibata, Kohei
AU - Fujita, Nobuyuki
N1 - Publisher Copyright:
© 2024 The Author(s)
PY - 2024/12
Y1 - 2024/12
N2 - Purpose: This study aimed to evaluate the effectiveness of a novel technique for securing the tibial component in cementless total knee arthroplasty (TKA) by utilizing resected cancellous bone to fill the peg holes. It was hypothesized that this method would reduce the incidence of radiolucent lines (RLLs) on plain radiographs. To test this hypothesis, a retrospective comparison of plain radiographs from patients who underwent the bone-filling technique (bone filling group) versus those who did not receive this treatment (conventional group) was conducted. Methods: Participants were 151 patients (213 joints) who underwent TKA with the NexGen trabecular metal (TM) modular tibia (Zimmer Biomet) from 2011 to 2016 [bone filling group, 54 patients (69 joints); conventional group, 100 patients (144 joints); 3 patients had 1 joint in each group]. Clinical evaluations, plain radiographs, and operative time were compared between groups. Results: The mean follow-up period was 5 years and 5 months. Knee Society Scores and Knee Society Functional Scores did not differ significantly between groups; however, the bone filling group had a significantly lower incidence of RLLs (p < 0.05) and significantly more longitudinal trabecular thickening below the pegs (p < 0.05). Multiple logistic regression analysis with the presence/absence of RLLs as the dependent variable revealed a significant effect of bone filling (odds ratio = 2.820, 95% confidence interval 1.033–7.700; p < 0.05). Conclusion: Concurrent peg hole bone filling significantly reduces the incidence of RLLs and significantly increases longitudinal trabecular thickening below the pegs during TKA with the NexGen TM modular tibial component.
AB - Purpose: This study aimed to evaluate the effectiveness of a novel technique for securing the tibial component in cementless total knee arthroplasty (TKA) by utilizing resected cancellous bone to fill the peg holes. It was hypothesized that this method would reduce the incidence of radiolucent lines (RLLs) on plain radiographs. To test this hypothesis, a retrospective comparison of plain radiographs from patients who underwent the bone-filling technique (bone filling group) versus those who did not receive this treatment (conventional group) was conducted. Methods: Participants were 151 patients (213 joints) who underwent TKA with the NexGen trabecular metal (TM) modular tibia (Zimmer Biomet) from 2011 to 2016 [bone filling group, 54 patients (69 joints); conventional group, 100 patients (144 joints); 3 patients had 1 joint in each group]. Clinical evaluations, plain radiographs, and operative time were compared between groups. Results: The mean follow-up period was 5 years and 5 months. Knee Society Scores and Knee Society Functional Scores did not differ significantly between groups; however, the bone filling group had a significantly lower incidence of RLLs (p < 0.05) and significantly more longitudinal trabecular thickening below the pegs (p < 0.05). Multiple logistic regression analysis with the presence/absence of RLLs as the dependent variable revealed a significant effect of bone filling (odds ratio = 2.820, 95% confidence interval 1.033–7.700; p < 0.05). Conclusion: Concurrent peg hole bone filling significantly reduces the incidence of RLLs and significantly increases longitudinal trabecular thickening below the pegs during TKA with the NexGen TM modular tibial component.
KW - Cementless
KW - Knee joint
KW - Retrospective study
KW - Total knee arthroplasty
KW - Trabecular bone
UR - https://www.scopus.com/pages/publications/105010884287
UR - https://www.scopus.com/pages/publications/105010884287#tab=citedBy
U2 - 10.1016/j.jjoisr.2024.09.001
DO - 10.1016/j.jjoisr.2024.09.001
M3 - Article
AN - SCOPUS:105010884287
SN - 2949-7051
VL - 2
SP - 151
EP - 156
JO - Journal of Joint Surgery and Research
JF - Journal of Joint Surgery and Research
IS - 4
ER -