Proposal for local diagnostic reference levels in general radiography in Japan

Yasuki Asada, Koji Ono, Yuya Kondo, Kazuma Sugita, Takuma Ichikawa, Hideki Shibata

Research output: Contribution to journalArticlepeer-review

8 Citations (Scopus)

Abstract

The present study aimed to propose local diagnostic reference levels (DRLs) formulated by calculating entrance surface doses for general radiography at 20 facilities of Aichi prefecture in Japan, by comparing these values with DRLs established in Japan in 2015 (DRLs 2015) and assessing radiation dose differences among facilities. X-ray outputs (half-value layer and air kerma) of each facility were measured with a non-invasive type of detector. The results were employed to formulate local DRLs based on the 75th percentiles of dose distributions. These local DRLs were lower than the DRLs 2015 for all examinations. If proposed local DRLs from other 46 prefectures can be collected, this paper can be used to benefit the next effort to draft better DRL for Japan.

Original languageEnglish
Pages (from-to)338-344
Number of pages7
JournalRadiation protection dosimetry
Volume187
Issue number3
DOIs
Publication statusPublished - 01-12-2019

All Science Journal Classification (ASJC) codes

  • Radiological and Ultrasound Technology
  • Radiation
  • Radiology Nuclear Medicine and imaging
  • Public Health, Environmental and Occupational Health

Fingerprint

Dive into the research topics of 'Proposal for local diagnostic reference levels in general radiography in Japan'. Together they form a unique fingerprint.

Cite this