Quality improvement of dual-energy lung perfusion image by reduction of low-energy X-ray spectrum: An evaluation on clinical images

Tatsuya Kawai, Yoshiyuki Ozawa, Masaki Ogawa, Kazuya Ohashi, Kazushi Suzuki, Yuta Shibamoto

Research output: Contribution to journalArticlepeer-review

1 Citation (Scopus)

Abstract

Background: The effects of the reduction of low-energy X-ray spectrum on lung perfusion images created by dual-energy CT have not been well evaluated. The aim of this study is to investigate the reliability of lung perfusion blood volume (PBV) images created by dual-energy CT (DECT) equipped with or without a tin filter, focusing on its accuracy adjacent to high-attenuation areas. Material/Methods: Among 176 patients who underwent DECT for suspicion of pulmonary embolism, 38 patients (mean age, 64; range, 16 to 83 years) without apparent evidence of pulmonary embolism were evaluated in this study. They underwent DECT at 100/140 kVp with a tin filter on 140 kVp tube (Group A; n=18) or at 80/140 kVp without the filter (Group B; n=20). On the lung PBV images, the degrees of artifacts – pulmonary enhancement defect (PED) and pseudo-enhancement in the trachea (PTE) adjacent to the vena cava were evaluated using a four-point scale (0=minimal to 3=prominent). Results: The mean degrees of artifact in Group A were significantly lower than those in Group B (0.8 vs. 1.9; P<0.0001 for PED, respectively, and 1.1 vs. 2.2; P<0.0001 for TPE, respectively). The mean CTDIvols were 4.90±1.14 and 12.98±3.15 mGy (P<0.0001) for Group A and Group B, respectively. Conclusions: The quality and accuracy of dual-energy lung perfusion image will be improved by using the tin filter technique.

Original languageEnglish
Pages (from-to)593-597
Number of pages5
JournalPolish Journal of Radiology
Volume81
DOIs
Publication statusPublished - 10-12-2016
Externally publishedYes

All Science Journal Classification (ASJC) codes

  • Radiology Nuclear Medicine and imaging

Fingerprint

Dive into the research topics of 'Quality improvement of dual-energy lung perfusion image by reduction of low-energy X-ray spectrum: An evaluation on clinical images'. Together they form a unique fingerprint.

Cite this