TY - JOUR
T1 - Quantitative optical frequency domain imaging assessment of in-stent structures in patients with ST-segment elevation myocardial infarction
T2 - Impact of imaging sampling rate
AU - Muramatsu, Takashi
AU - García-García, Hector M.
AU - Lee, Il Soo
AU - Bruining, Nico
AU - Onuma, Yoshinobu
AU - Serruys, Patrick W.
PY - 2012
Y1 - 2012
N2 - Background: The impact of the sampling rate (SR) of optical frequency domain imaging (OFDI) on quantitative assessment of in-stent structures (ISS) such as plaque prolapse and thrombus remains unexplored. Methods and Results: OFDI after stenting was performed in ST-segment elevation myocardial infarction (STEMI) patients using a TERUMO OFDI system (Terumo Europe, Leuven, Belgium) with 160frames/s and pullback speed of 20mm/s. A total of 126 stented segments were analyzed. ISS were classified as either attached or non-attached to stent area boundaries. The volume, mean area and largest area of ISS were assessed according to 4 frequencies of SR, corresponding to distances between the analyzed frames of 0.125, 0.25, 0.50 and 1.0mm. ISS volume was calculated by integrating cross-sectional ISS areas multiplied by each sampling distance using the disk summation method. The volume and mean area of ISS became significantly larger, while the largest area became significantly smaller as sampling distance became larger (1.11 mm2 for 0.125 mm vs. 1.00 mm2 for 1.0 mm, P for trend=0.036). In addition, variance of difference was positively associated with increasing width of sampling distance. Conclusions: Quantification of ISS is significantly influenced by the applied frequency of SR. This should be taken into account when designing future OFDI studies in which quantitative assessment of ISS is critical for the evaluation of STEMI patients.
AB - Background: The impact of the sampling rate (SR) of optical frequency domain imaging (OFDI) on quantitative assessment of in-stent structures (ISS) such as plaque prolapse and thrombus remains unexplored. Methods and Results: OFDI after stenting was performed in ST-segment elevation myocardial infarction (STEMI) patients using a TERUMO OFDI system (Terumo Europe, Leuven, Belgium) with 160frames/s and pullback speed of 20mm/s. A total of 126 stented segments were analyzed. ISS were classified as either attached or non-attached to stent area boundaries. The volume, mean area and largest area of ISS were assessed according to 4 frequencies of SR, corresponding to distances between the analyzed frames of 0.125, 0.25, 0.50 and 1.0mm. ISS volume was calculated by integrating cross-sectional ISS areas multiplied by each sampling distance using the disk summation method. The volume and mean area of ISS became significantly larger, while the largest area became significantly smaller as sampling distance became larger (1.11 mm2 for 0.125 mm vs. 1.00 mm2 for 1.0 mm, P for trend=0.036). In addition, variance of difference was positively associated with increasing width of sampling distance. Conclusions: Quantification of ISS is significantly influenced by the applied frequency of SR. This should be taken into account when designing future OFDI studies in which quantitative assessment of ISS is critical for the evaluation of STEMI patients.
UR - http://www.scopus.com/inward/record.url?scp=84870496028&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=84870496028&partnerID=8YFLogxK
U2 - 10.1253/circj.CJ-12-0536
DO - 10.1253/circj.CJ-12-0536
M3 - Article
C2 - 22971949
AN - SCOPUS:84870496028
SN - 1346-9843
VL - 76
SP - 2822
EP - 2831
JO - Circulation Journal
JF - Circulation Journal
IS - 12
ER -