Reliability of stiffness measurement device during passive isokinetic spastic wrist movements of healthy subjects and hemiplegics

Abbas Orand, Hiroyuki Miyasaka, Kotaro Takeda, Genichi Tanino, Takeshi Chihara, Hidehiko Beppu, Shigeru Sonoda

Research output: Contribution to journalArticle

2 Citations (Scopus)

Abstract

The consistency of torque measurements during repetitive moving arm movements and also during passive wrist movements at two angular velocities of slow (∼6°/s) and moderate (∼120°/s) was investigated. The designed and developed device was applied to 3 cases, to a spring, to 8 able-bodied subjects and to 2 hemiplegic patients. While the mean of the intra-class correlation coefficient of subjects were 0.65 and 0.75 for slow and moderate angular velocities, those of the hemiplegic patients and the spring respectively ranged between excellent values of 0.93–1 and 0.91–1. The Pearson's product-moment correlation coefficients of the 3 cases for the 2 slow and moderate angular velocities ranged between 0.80 and 1. We could verify that the device can be used in our future researches and it can (1) reliably rotate a moving arm horizontally with angular velocities between 3 and 350°/s constantly in a range of motion between −60 and 60° and (2) simultaneously capture the data of angular displacement, torque, and two electromyogram activities. For the standardization of our future studies with the device, we could verify the stability of the last two repeated passive wrist movements in case of patients. The results of the study with the able-bodied subjects are also important as a reference for our studies with the hemiplegic.

Original languageEnglish
Pages (from-to)114-123
Number of pages10
JournalBiocybernetics and Biomedical Engineering
Volume37
Issue number1
DOIs
Publication statusPublished - 01-01-2017

Fingerprint

Angular velocity
Stiffness
Torque measurement
Standardization
Torque

All Science Journal Classification (ASJC) codes

  • Biomedical Engineering

Cite this

@article{ab8d3d2db5124c5587e08b2495b99d63,
title = "Reliability of stiffness measurement device during passive isokinetic spastic wrist movements of healthy subjects and hemiplegics",
abstract = "The consistency of torque measurements during repetitive moving arm movements and also during passive wrist movements at two angular velocities of slow (∼6°/s) and moderate (∼120°/s) was investigated. The designed and developed device was applied to 3 cases, to a spring, to 8 able-bodied subjects and to 2 hemiplegic patients. While the mean of the intra-class correlation coefficient of subjects were 0.65 and 0.75 for slow and moderate angular velocities, those of the hemiplegic patients and the spring respectively ranged between excellent values of 0.93–1 and 0.91–1. The Pearson's product-moment correlation coefficients of the 3 cases for the 2 slow and moderate angular velocities ranged between 0.80 and 1. We could verify that the device can be used in our future researches and it can (1) reliably rotate a moving arm horizontally with angular velocities between 3 and 350°/s constantly in a range of motion between −60 and 60° and (2) simultaneously capture the data of angular displacement, torque, and two electromyogram activities. For the standardization of our future studies with the device, we could verify the stability of the last two repeated passive wrist movements in case of patients. The results of the study with the able-bodied subjects are also important as a reference for our studies with the hemiplegic.",
author = "Abbas Orand and Hiroyuki Miyasaka and Kotaro Takeda and Genichi Tanino and Takeshi Chihara and Hidehiko Beppu and Shigeru Sonoda",
year = "2017",
month = "1",
day = "1",
doi = "10.1016/j.bbe.2016.09.001",
language = "English",
volume = "37",
pages = "114--123",
journal = "Biocybernetics and Biomedical Engineering",
issn = "0208-5216",
publisher = "PWN-Polish Scientific Publishers",
number = "1",

}

Reliability of stiffness measurement device during passive isokinetic spastic wrist movements of healthy subjects and hemiplegics. / Orand, Abbas; Miyasaka, Hiroyuki; Takeda, Kotaro; Tanino, Genichi; Chihara, Takeshi; Beppu, Hidehiko; Sonoda, Shigeru.

In: Biocybernetics and Biomedical Engineering, Vol. 37, No. 1, 01.01.2017, p. 114-123.

Research output: Contribution to journalArticle

TY - JOUR

T1 - Reliability of stiffness measurement device during passive isokinetic spastic wrist movements of healthy subjects and hemiplegics

AU - Orand, Abbas

AU - Miyasaka, Hiroyuki

AU - Takeda, Kotaro

AU - Tanino, Genichi

AU - Chihara, Takeshi

AU - Beppu, Hidehiko

AU - Sonoda, Shigeru

PY - 2017/1/1

Y1 - 2017/1/1

N2 - The consistency of torque measurements during repetitive moving arm movements and also during passive wrist movements at two angular velocities of slow (∼6°/s) and moderate (∼120°/s) was investigated. The designed and developed device was applied to 3 cases, to a spring, to 8 able-bodied subjects and to 2 hemiplegic patients. While the mean of the intra-class correlation coefficient of subjects were 0.65 and 0.75 for slow and moderate angular velocities, those of the hemiplegic patients and the spring respectively ranged between excellent values of 0.93–1 and 0.91–1. The Pearson's product-moment correlation coefficients of the 3 cases for the 2 slow and moderate angular velocities ranged between 0.80 and 1. We could verify that the device can be used in our future researches and it can (1) reliably rotate a moving arm horizontally with angular velocities between 3 and 350°/s constantly in a range of motion between −60 and 60° and (2) simultaneously capture the data of angular displacement, torque, and two electromyogram activities. For the standardization of our future studies with the device, we could verify the stability of the last two repeated passive wrist movements in case of patients. The results of the study with the able-bodied subjects are also important as a reference for our studies with the hemiplegic.

AB - The consistency of torque measurements during repetitive moving arm movements and also during passive wrist movements at two angular velocities of slow (∼6°/s) and moderate (∼120°/s) was investigated. The designed and developed device was applied to 3 cases, to a spring, to 8 able-bodied subjects and to 2 hemiplegic patients. While the mean of the intra-class correlation coefficient of subjects were 0.65 and 0.75 for slow and moderate angular velocities, those of the hemiplegic patients and the spring respectively ranged between excellent values of 0.93–1 and 0.91–1. The Pearson's product-moment correlation coefficients of the 3 cases for the 2 slow and moderate angular velocities ranged between 0.80 and 1. We could verify that the device can be used in our future researches and it can (1) reliably rotate a moving arm horizontally with angular velocities between 3 and 350°/s constantly in a range of motion between −60 and 60° and (2) simultaneously capture the data of angular displacement, torque, and two electromyogram activities. For the standardization of our future studies with the device, we could verify the stability of the last two repeated passive wrist movements in case of patients. The results of the study with the able-bodied subjects are also important as a reference for our studies with the hemiplegic.

UR - http://www.scopus.com/inward/record.url?scp=85012298979&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=85012298979&partnerID=8YFLogxK

U2 - 10.1016/j.bbe.2016.09.001

DO - 10.1016/j.bbe.2016.09.001

M3 - Article

AN - SCOPUS:85012298979

VL - 37

SP - 114

EP - 123

JO - Biocybernetics and Biomedical Engineering

JF - Biocybernetics and Biomedical Engineering

SN - 0208-5216

IS - 1